Hematology Analyzer
DIRUI BCC-3600
Rated 0 out of 5
In stock
SKU:
PGA-DIRUIBCC3600
| Parameter | WBC, RBC, HGB, MCV, MCH, MCHC, HCT, PLT, NEUT#, MXD#. LYM#, NEUT%, MXD%, LYM%, RDW-CV, RDW-SD, PDW, MPV, PCT, P-LCR, PLCC |
|---|---|
| Histogram | WBC, RBC, PLT |
| Principles | WBC, RBC, PLT: electrical impedance HGB: cyanide-free colorimetri |
| Cross Contamination | WBC, RBC, HGB<0.5%, PLT<1% |
| Aparture Diameter | WBC 100 µm, RBC/PLT 70µm |
| Sample Consumtion | Whole blood 6 µL, Pre diluted blood 20µL |
| Throughput | 60 samples/ hour |
| Display | 10.2 inch touch screen, Resolution: 1024 X 600 |
| Reagent | Detergent, Diluent, BCC-3600 Lyse |
| Multiply QC Method | L-J, X : 12QC files, 30 result/file 16 : X-B: 1 file, 150 result/file |
| Calibration | Manual calibration, automatic calibration, fresh blood calibration |
| Counting mode | whole blood and pre -diluted blood |
| Input/Output | Build in thermal printer, RS232, USB |
| Environment Requirement | Ambient temperature 18⁰C-30⁰C, Relative humidity ≤75% |
| Power Supply | 100-240 VAC 50/60 HZ |
| Dimension (mm) | 430 (L) x 395 (W) x 432 (H) |
| Weight | 25 Kg |
Hemaray 51
Rated 0 out of 5
In stock
SKU:
PGA-HEMARAY51
| Principles | Electrical impedance, Colorimetry; Laser scattering method |
|---|---|
| Parameters | WBC, BAS # BSA %, NEU # EOS # EOS %, LYM # LYM %, MON # MON %, RBC, HGB, HCT, MCV, KIA, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR, P-LCC; ALY # ALY %, LIC # LIC %; WBC Histogram, RBC Histogram, PLT Histogram; 2D DIFF Scatter gram x3; 3D DIFF Scatter gram x1; |
| Sample Consumption | Whole blood 15ul (CBC+DIFF/CBC) Pre-diluted 20ul (CBC+DIFF/CBC) |
| Testing Mode | CBC, CBC+DIFF |
| Reagents | RD-50 Diluent, RL-50D Iyse, RL-50H Iyse |
| Throughput | 60 s/h |
| Optional External Devices | Bar-code reader, Mouse, Keyboard, External printer |
| Sample Types | Whole blood, peripheral whole blood, pre-diluted blood |
| System | Integrated windows system displayed by 10.4 inches color touch screen. Bi-directional LIS Communication |
| Link ports | LAN; USB x 4 |
| Working Environment | 10C ~ 30C; Humidity < 85% |
| Data Storage | 100000 results |
| Power | 110V-240V; 50Hz/60Hz; 400VA |
| Printer | Internal thermal printer |
| Size & Weight | Size (mm) 365 x 470 x 525 Weight : 35Kg |
Medonic M16/M20
Rated 0 out of 5
In stock
SKU:
PGA-MEDONICM16/M20
| Reagen | 2 Jenis Reagen yang digunakan |
|---|---|
| Prinsip Pengukuran | WBC, RBC, PLT Impedansi |
| Prinsip Pengukuran HGB | Fotometer, metode bebas Cyanide 535 nm + 5nm HGB otomatis blank setiap sampel |
| WBC Diskriminator terprogram | Ya, diskriminator tersebar |
| Sistem Sampel | Katup geser tertutup |
| Sistem Diskriminator RBC/PLT | Ya |
| Sistem Analisis Sampel | Open inlet dan PRE-Dilute |
| Volume Sampel darah open inlet / predilute | <90ul/20ul |
| Pembacaan Sampel open inlet | 53 detik |
| Jumlah sampel/jam | 67 sampel |
| Parameter yang dilaporkan | 16 parameter : WBC, HGB, RBC, PLT, HCT, MCV, RDW, MPV, MCH, MCHC, LYM%, LYM, MID%, MID, GRAN%, GRAN RDW, PDW, PCT, LPCR |
| Parameter adapat di upgrade | Ya, 16 parameter menjadi 20 parameter, software tambahan. |
| Carry-over | RBC, HGB, WBC<1% PLT <2% |
| CV | WBC <1.8%, RBC <1.1%; MCV<0.3%; PLT<3.3%; HGB <1.0% |
| LCD | Berwarna, layar sentuh TFT |
| Pembaca barcode | Ya |
| Printer | Eksternal, port tersedia |
| Bahasa Software | Inggris, Indonesia, dll. |
| Serial Output | Ya (sesuai standar EN 60950) |
| Tegangan | 230V fuse 5x20mm T1, 6A, 250V 120V fuse 5x20mm T3, 15A, 250V |
| Konsumsi Listrik | Max 100VA Max 20VA (Standby) |
| Frekuensi | 50/60HZ |
| Temperatur | 18-32 C (64-90 F) |
| Kelembaban | Hingga 80% |
| Dimensi, Berat, Sertifikat | 41x29x46cm (P x L x T) <18kg, versi standar ISO, CE, EMC, AKL-DEPKES |
Mindray BC 30
Rated 0 out of 5
In stock
SKU:
PGA-MIDNRAYBC30
| Principles | Impedance method for WBC, RBC and PLT counting Cyanide free reagent for hemoglobin test |
|---|---|
| Parameters | 21 parameters: WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR,P-LCC 3 histograms for WBC, RBC and PLT |
| Sample Volume | Prediluted mode ≤20μL Whole blood mode ≤9 μL |
| Performance | Parameter Linearity Range Precision (CV %) Carryover WBC(109/L) 0-300 ≤3.5% (4.0-6.9) ≤0.5% ≤2.0% (7.0-15.0) RBC(1012/L) 0-8.00 ≤1.5% (3.50-6.5) ≤0.5% HGB(g/L) 0-280 ≤1.5% (100-180) ≤0.5% MCV(fL) ≤0.5% (70.0-110.0) ≤0.5% PLT(109/L) 0-4000 ≤5.0% (100-149) ≤1.0% ≤4.0% (150-500) |
| Throughput | 60 samples per hour |
| Display | 10.4 inch TFT Touch Screen |
| Multi Language | Chinese, English, Spanish, Portuguese, Russian, French, Bahasa Indonesia |
| Data storage capacity | Up to 400,000 results including numeric and graphical information |
| Communication | LAN Port supports HL7 protocol Support bi-directional LIS |
| Interface | 4 USB ports (for external printer, software upgrade, barcode reader, external WIFI, keyboard and mouse), LAN port (1) |
| Printout | Thermal recorder, 50 mm wide paper, various printouts formats External printer optional |
| Power Requirement | (100V-240V)±10% ≤180VA (50Hz/60Hz) ±1Hz |
| Dimension and Weight | Dimension: Depth (410 mm) x width (300 mm) x height (400 mm) Weight: ≤20Kg |
Mindray BC 30s
Rated 0 out of 5
In stock
SKU:
PGA-MIDNRAYBC30s
| Principles | Impedance method for WBC, RBC and PLT counting Cyanide free reagent for hemoglobin test |
|---|---|
| Parameters | 21 parameters: WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR,P-LCC 3 histograms for WBC, RBC and PLT |
| Reagent | M-30D DILUENT M-30CFL LYSE PROBE CLEANSER |
| Sample Volume | Prediluted mode 20μL Whole blood mode 9 μL |
| Performance | Parameter Linearity Range Precision (CV %) Carryover WBC(109/L) 0-200 ≤3.5% (4.0-6.9) ≤0.5% ≤2.0% (7.0 -15.0) RBC(1012/L) 0-8.00 ≤1.5% (3.5-6.5) ≤0.5% HGB(g/L) 0-280 ≤1.5% (100 -180) ≤0.5% MCV(fL) ≤1.0% (70 -110) PLT(109/L) 0-4000 ≤5.0% (100 -149) ≤1.0% ≤4.0% (150 -500) |
| Throughput | 70 samples per hour |
| Display | 10.4 inch TFT Touch Screen |
| Multi Language | Chinese, English, Spanish, Portuguese, Russian, French, Bahasa Indonesia |
| Data storage capacity | Up to 500,000 results including numeric and graphical information |
| Communication | LAN Port supports HL7 protocol Support bi-directional LIS |
| Interface | 4 USB port (for external printer, software upgrade, barcode reader, WIFI adapter,keyboard and mouse), LAN port (1) |
| Printout | Thermal recorder, 50 mm wide paper, various printouts formats External printer optional |
| Operating Environment | Temperature: 10°C~40°C Humidity: 10%~90% Air pressure: 70kPa~106kPa |
| Power Requirement | 100V-240V ≤300VA 50Hz/60Hz |
| Dimension and Weight | Dimension: Depth(410 mm) x width(300 mm) x height(400 mm) Weight: ≤20Kg |
Mindray BC 700 & BC 720
Rated 0 out of 5
In stock
SKU:
PGA-MIDNRAYBC700
| Principles | WBC (IMG/Neu/Mon/Lym/Eos/Bas), NRBC/RET*,PLT-H/PLT-O*/IPF: SF Cube ^ Cell Analysis Technology ^S: Scatter; F: Fluorescence; Cube: 3D analysis |
|---|---|
| RBC, PLT | Focusing Flow-DC Impedance Method |
| HGB | Colorimetric method |
| ESR | Photometric method |
| Number of measuring parameters (whole blood): | 109 |
| Number of measuring parameters (body fluid): | 18 |
| Number of reportable parameters: | 7 WBC-BF TC-BF# MN# MN% PMN# PMN% RBC-BF |
| Number of research parameters: | 11 |
| Sample volume | CD (whole blood): 23ul CD+ESR (whole blood): 160ul Predilute: 20ul |
| Data storage capacity | Up to 150,000 results including numeric and graphical information * |
| Throughput | CD 80t/h CDR 45t/h CD+ESR 40t/h |
| Whole blood | CBC, CBC + DIFF, CBC + DIFF + RET*, CD + ESR, CDR + ESR*, CD/WBC-3X, CDR/PLT-5X*, and other modes |
| Predilute | CBC, CBC + DIFF, CDR*, and other modes |
| Body fluid | CBC + DIFF |
| Dimensions | 500D x 325W x 450H mm |
| Weight | ≤35Kg |
| Voltage | 100V-240V~ (±10%) |
| Frequency | 50Hz/60Hz (±1Hz) |
| Power input | 300VA |
| External output | LAN x 1 , USB x 4 (Specifications: DC 5V; 500mA; USB 2.0 x 3; USB 3.0 x 1) |
| Ambient temperature | 10℃ ~ 35℃ |
| Relative humidity | 30% ~ 85% |
| Atmospheric pressure: | 70.0kPa ~ 106.0kPa^ ^Note : Required altitude for normal operation: -400m ~ +3000m |
| Performance | Parameter Linearity Range Precision Carryover WBC 0-500×10^9 /L ≤2.5% (≥4.51×10^9 /L) ≤ 1.0% RBC 0-8.60×10^12/L ≤1.5% (≥3.5×10^12/L) ≤ 1.0% HGB 0-260g/L ≤1.0% (110-180g/L) ≤ 1.0% HCT 0-75% ≤1.5% (30%-50%) ≤ 1.0% PLT* 0-5000×10^9 /L ≤ 1.5(SD) (≤20×10^9/L)^ ≤ 1.0% ≤ 2.5% (≥100×10^9/L)^ RET* 0-0.8×10^12/L ≤15% (RBC ≥ 3.00×10^12/L ≤ 1.0% RET%: 1.00% ~ 4.00%) ESR ≤1.8(SD)(0~20mm/h) ≤ 1.0% ^ Note: Applicable only to CDR/PLT-O 5x and CR/PLT-O 5x models Items marked with an asterisk (*) apply only to BC-720 |
Mindray BC 760 & BC 780
Rated 0 out of 5
In stock
SKU:
PGA-MIDNRAYBC760
| Principles | WBC (IMG/Neu/Mon/Lym/Eos/Bas), NRBC/RET*,PLT-H/PLT-O*/IPF: SF Cube ^ Cell Analysis Technology ^S: Scatter; F: Fluorescence; Cube: 3D analysis |
|---|---|
| RBC, PLT | Focusing Flow-DC Impedance Method |
| HGB | Colorimetric method |
| ESR | Photometric method |
| Number of measuring parameters (whole blood): | 109 |
| Number of measuring parameters (body fluid): | 18 |
| Number of reportable parameters: | 7 WBC-BF TC-BF# MN# MN% PMN# PMN% RBC-BF Number of research parameters: 11 |
| Sample volume | CD (whole blood): 25ul CD+ESR (whole blood): 160ul Predilute: 20ul |
| Data storage capacity | Up to 150,000 results including numeric and graphical information * |
| Throughput | CD 80t/h CDR 45t/h CD+ESR 40t/h |
| Whole blood | CBC, CBC + DIFF, CBC + DIFF + RET*, CD + ESR, CDR + ESR*, CD/WBC-3X, CDR/PLT-5X*, and other modes |
| Predilute | CBC, CBC + DIFF, CDR*, and other modes |
| Body fluid | CBC + DIFF |
| Dimensions | 840D x 655W x 600H mm |
| Weight | ≤70.6Kg |
| Voltage | 100V-240V~ (±10%) |
| Frequency | 50Hz/60Hz (±1Hz) |
| Power input | 600VA |
| External output | LANx1 , USB x 4 (Specifications: DC 5V; 500mA; USB2.0 x 3; USB3.0 x 1 ) |
| Ambient temperature | 10℃ ~ 35℃a |
| Relative humidity | 30% ~ 85% |
| Atmospheric pressure: | 70.0kPa ~ 106.0kPa^ ^Note : Required altitude for normal operation: -400m ~ +3000m |
| Performance | Parameter Linearity Range Precision Carryover WBC 0-500×10^9 /L ≤2.5% (≥4.51×10^9 /L) ≤ 1.0% RBC 0-8.60×10^12/L ≤1.5% (≥3.5×10^12/L) ≤ 1.0% HGB 0-260g/L ≤1.0% (110-180g/L) ≤ 1.0% HCT 0-75% ≤1.5% (30%-50%) ≤ 1.0% PLT* 0-5000×10^9 /L ≤ 1.5(SD) (≤20×10^9/L)^ ≤ 1.0% ≤ 2.5% (≥100×10^9/L)^ RET* 0-0.8×10^12/L ≤15% (RBC ≥ 3.00×10^12/L ≤ 1.0% RET%: 1.00% ~ 4.00%) ESR ≤1.8(SD)(0~20mm/h) ≤ 1.0% ^ Note: Applicable only to CDR/PLT-O 5x and CR/PLT-O 5x models Items marked with an asterisk (*) apply only to BC-720 |
Mindray BC-10
Rated 0 out of 5
In stock
SKU:
PGA-MIDNRAYBC10
| Principles | Impedance method for WBC, RBC and PLT counting Cyanide free reagent for hemoglobin test |
|---|---|
| Parameters | 20 parameters: WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR 3 histograms for WBC, RBC and PLT |
| Sample Volume | Prediluted mode ≤20μL Whole blood mode ≤9 μL |
| Performance | Parameter Linearity Range Precision (CV %) Carryover WBC(109/L) 0-100 ≤3.5% (4.0-6.9) ≤0.5% ≤2.0% (7.0-15.0) RBC(1012/L) 0-8.00 ≤2.0% (3.50-6.5) ≤0.5% HGB(g/L) 0-280 ≤2.0% (100-180) ≤0.5% MCV(fL) ≤1.0% (70.0-110.0) ≤0.5% PLT(109/L) 0-1000 ≤5.0% (100-500) ≤1.0% |
| Throughput | 30 samples per hour |
| Display | 8.4 inch TFT Touch Screen |
| Multi-language | Chinese, English, Spanish, Portuguese, Russian, French, Bahasa Indonesia |
| Data Storage Capacity | Up to 50,000 results including numeric and graphical information |
| Communication | LAN Port supports HL7 protocol Support bi-directional LIS |
| Interface | 4 USB ports (for external printer, software upgrade, barcode reader, external WIFI, keyboard and mouse), LAN port (1) |
| Printout | Thermal recorder, 50 mm wide paper, various printouts formats |
| Power Requirement | (100V-240V)±10% ≤180VA (50Hz/60Hz) ±1Hz |
| Dimension | Depth (410 mm) x width (300 mm) x height (400 mm) |
| Weight | ≤20Kg |
Mindray BC-11
Rated 0 out of 5
In stock
SKU:
PGA-MIDNRAYBC11
| Principles | Impedance method for WBC, RBC and PLT counting Cyanide free reagent for hemoglobin test |
|---|---|
| Parameters | 20 parameters: WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR 3 histograms for WBC, RBC and PLT 2 research parameters: NLR, PLR |
| Sample Volume | Prediluted mode ≤20μL Whole blood mode ≤9 μL |
| Performance | Parameter Linearity Range Precision (CV %) Carryover WBC(109/L) 0-100 ≤3.5% (4.0-6.9) ≤0.5% ≤2.0% (7.0-15.0) RBC(1012/L) 0-8.00 ≤2.0% (3.50-6.5) ≤0.5% HGB(g/L) 0-280 ≤2.0% (100-180) ≤0.5% MCV(fL) ≤1.0% (70.0-110.0) ≤0.5% PLT(109/L) 0-1000 ≤5.0% (100-500) ≤1.0% |
| Throughput | 30 samples per hour |
| Display | 8.4 inch TFT Touch Screen |
| Multi-language | Chinese, English, Spanish, Portuguese, Russian, French, Bahasa Indonesia |
| Data Storage Capacity | Up to 50,000 results including numeric and graphical information |
| Communication | LAN Port supports HL7 protocol Support bi-directional LIS |
| Interface | 4 USB ports (for external printer, software upgrade, barcode reader, external WIFI, keyboard and mouse), LAN port (1) |
| Printout | Thermal recorder, 50 mm wide paper, various printouts formats |
| Power Requirement | (100V-240V)±10% ≤180VA (50Hz/60Hz) ±1Hz Temperature: 15°C~30°C Humidity: 10%~90% Air pressure: 70kPa~106kPa |
| Dimension | Depth (410 mm) x width (300 mm) x height (400 mm) |
| Weight | ≤20Kg |
Mindray BC-2800
Rated 0 out of 5
In stock
SKU:
PGA-MINDRAYBC2800
| Parameter | WBC, Lymph #, Mid #, Gran #, Lymph%, Mid%, Gran%, RBC, HGB, HCT, MCV, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT dan Histogram untuk WBC, RBC, PLT |
|---|---|
| Prinsip | Metode impedansi listrik untuk penghitungan dan metode bebas sianida untuk hemoglobin. |
| Kinerja | Parameter Linearity Range Precision (CV%) WBC (10⁹ / L) 0,0-99.9 3 (4.0-15.0) RBC (10¹² / L) 0,0-9,99 2 (3,0-6,5) HGB (g / L) 0-300 2 (100-180) MCV (fL) 1 (70-100) PLT (10⁹ / L) 0-999 5 (200-500) |
| Volume Contoh | Prediluted 20 μL Seluruh Darah 13 μL |
| Diameter Lubang | 80 μm |
| Throughput | 30 sampel per jam |
| Time to result, open tube inlet | <50 sec |
| Display | Layar LCD berwarna Resolusi: 640 x 480 |
| Menopang | WBC, RBC, HGB≤0,5%, PLT≤1% |
| Input output | RS232 x 2, 1 printer paralel (opsional), pemindai kode 1 bar (opsional) 1 antarmuka keyboard |
| Printer | Perekam thermal, kertas lebar 50mm, banyak format cetakan, printer opsional |
| Lingkungan operasi | Suhu: 15 ° C ~ 30 ° C Kelembaban: 30% ~ 85% |
| Kebutuhan daya | AC100-240V, 50 / 60Hz |
| Dimensi | 322 (W) x 437 (H) x 386 (D) |
| Berat | 17,9 Kg |
Mindray BC-3000 Plus
Rated 0 out of 5
In stock
SKU:
PGA-MINDRAYBC3000P
| Parameter | WBC, Lymph #, Mid #, Gran #, Lymph #, Mid%, Gran%, Lymph%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT dan Histogram untuk WBC, RBC, PLT |
|---|---|
| Prinsip | Metode impedansi listrik untuk penghitungan dan metode bebas sianida untuk hemoglobin. |
| Kinerja | Paramter Linearity Range Precision (CV%) WBC (109 / L) 0,3-99,9 2,5 (7,0-15,0) RBC (1012 / L) 0. 20 – 8.00 2 (3,50 -6. 00) HGB (g / L) 10-250 1. 5 (110 -180) MCV (fL) 0. 5 (80,0-11 0,0) PLT (109 / L) 10-999 5 (150-500) |
| Volume Contoh | Prediluted 20 μL Seluruh Darah 13 μL |
| Diameter Lubang | WBC 100 µm RBC / PLT 70 µm |
| Throughput | 60 sampel per jam |
| Display | Layar LCD warna besar Resolusi: 800 x 600 Alarm – 41 pesan kesalahan |
| Menopang | WBC, RBC, HGB ≤ 0,5%, PLT ≤ 1% |
| Input output | RS232 x 2, 1 printer paralel (opsional), pemindai kode 1 bar (opsional) 1 antarmuka keyboard |
| Printer | ThermaI recorde, kertas lebar 50 mm, banyak format cetakan, printer opsional |
| Lingkungan operasi | Suhu 15 ° C ~ 30 ° C Kelembaban 30% ~ 85% |
| Kebutuhan daya | AC 100-240V, 50 / 60Hz |
| Dimensi | 390 (W) x 460 (H) x 400 (D) |
| Berat | 21 Kg |