Showing all 8 results
Photometer adalah alat laboratorium yang digunakan untuk mengukur intensitas cahaya yang melewati atau dipantulkan oleh suatu sampel.
Dalam bidang kimia klinik, photometer berperan penting dalam analisis kuantitatif zat kimia berdasarkan prinsip spektrofotometri.
Alat Photometer
AMS NB-201
Rated 0 out of 5
In stock
SKU:
PGA-AMSNB-201
| Sumber Cahaya | Quartz Halogen Lamp 12V/20W |
|---|---|
| Rentang Panjang Gelombang | • Automatic By 8 Position Filter Wheel • 7 Standart Filiter ; 340nm, 405nm, 492nm, 510nm, 546nm, 578nm, 630nm • 1 Position Free For Optional Filter • Half Bandwidth <8 Nm • Stray Light ; <0.3% At 340nm |
| Rentang Fotometrik | • 0,0000 Hingga 3,0000 ABS • Resolusi; 0,0001 ABS • Stabilitas; 0,002 A/Jam |
| Flowcell | • Stainless Steel With Quartz Window • Measuring Volume 32 µl • Optical Path 10mm • Aspirition Volume Programmable ; 200-300 µl • Carryover <1.0% |
| Metode Analisis | • End-Point, Dengan Atau Tanpa Reagen Kosong • End-Point, Dengan Sampel Hambar, Dengan Atau Tanpa Reagen Kosong • Kinetik, Dengan Atau Tanpa Pemeriksaan Linieritas • Kinetik Dua Titik/Waktu Tetap, Dengan Atau Tanpa Reagen Kosong • Absorbance • Turbidimetry • Kalibrasi Linier Dan Non-Linier |
| Pengaturan Parameter | • Metode • Panjang Gelombang • Suhu • Reagen Kosong Y/N • Sampel Kosong Y/N • Jeda Waktu • Waktu Pengukuran • Waktu Reaksi • Batas Serapan • Volume Aspirasi • Standar • Pemeriksaan Linearitas • Satuan Untuk Hasil |
| Penyimpanan | • 112 Profil Uji • 3200 Hasil Sampel |
| Pengatur Suhu | By Means Of Pelitier Elements 25oC, 30oC, 37oC + 0.1oC |
| Input | Layar Sentuh |
| Tampilan | Layar LCD Besar |
| Perekam Termal Bawaan | |
| Interface | RS-232 Serial Port |
| Operating Environment | • Suhu : 10C – 30C • Kelembaban : < 70% |
| Kebutuhan Daya | AC 220V/110V + 10%, 50Hz + 2% |
| Dimensi | (P) 420mm x (L) 380mm x (T) 170mm |
| Berat | 8.5 kg |
BIOC Intherma 168
Rated 0 out of 5
In stock
SKU:
PGA-INTHERMA168
| Optic | 340, 405, 505, 546, 578, 620, 670nm. One more optional filter. |
|---|---|
| Light Source | Hologen 6V / 10W. |
| Resolution | 0.001Abs. |
| Photometric Range | 0.000-3 . 000Abs. |
| Stability Of Absorbency | Change<0.005 Abs per hour. |
| Repeatability | CV<0,5 %. |
| Carry over | < 1% |
| Linearity | R>0.999. |
| Flow Cell | 32 ul with peltier temperature control (25′C, 30′C, 37′C). |
| Memory | 200 Tets programs and over 100.000 test result. |
| Display | 7″ TFT LCD. |
| Printer | Builth-in thermal printer. |
| Data Communication | RS-232, SD card and USB. |
| CPU | High speed embedded processor. |
| Power Supply | AC 100-240V, 50/60Hz. |
| Weight | 7 Kg. |
| Dimension (mm) | 420(L) x 310(W) x 152(H). |
BS 3000M SINNOWA
Rated 0 out of 5
In stock
SKU:
PGA-BS3000M
| Methods | End point, Two points, Multi standard, Kinetic, Bichromatic and Serum blank, ect. |
|---|---|
| Test Program | 200 items, which may be modified and deleted |
| Capacity of Flow Cell | 32ul |
| Temperature Control | 25 ℃, 30 ℃, 37±0.1, room temperature. |
| Optical System: | Interferential filters, 340 / 405 / 492 / 510 / 546 / 578 / 620nm and two more filters available. |
| Light Source | 6V 10W halogen lamp. |
| Photometric Range | 0-2.5A |
| Display | LCD screen |
| Printer: | Built-in thermal printer |
| Serial Output | RS-232 standard |
| Dimension | 39cm×37cm×18cm |
Glory 127
Rated 0 out of 5
In stock
SKU:
PGA-GLORY127
| Reading Cuvette | Both flow through cell and direct reading cuvette |
|---|---|
| Photometric System | Light Source 6V/10W halogen lamp |
| Wavelength | 340/405/492/510/546/578/620nm, 2 more filter on request |
| Wavelength Accuracy | 2nm |
| Thermostatic Control | Temperatur 25C, 30C, 37C, Precision 2nm |
| Measuring System | Method : End Point, Fixed Time, Multistandart, Differential, Bichromatic and Immunoturbidimetric. |
| Measuring Range | 0-3.000 O.D |
| Photometric Linearity | 2% (0-3.000 O.D) |
| Photometeric Accuracy | 1% (0-3.000 O.D) |
| Storage | Over 200 programs, 1000 test result |
| Incubator | 20 incubating positions |
| Display | Black-illuminated LCD |
| Printer | Built in thermal printer |
| Interface | RS-232 Serial port for additional PC, USB port on request |
| Power Supply | AC110V / 60Hz or 220V / 50Hz |
| Dimensions | 340mm, 380mm, 180mm |
| Weight | 8.0 Kg |
Microlab 300
Rated 0 out of 5
In stock
SKU:
PGA-MICROLAB300
| Light Source | Quartz-iodine lamp 12V-20W. |
|---|---|
| Wavelength Range | Optical unit with 12 position filter wheel 340, 405, 505, 546, 578, 620 nm standard installed 6 positions for optional filters. |
| Photometric Range | 0.1 to 2.3 Absorbance Resolution 0.001 Abs. |
| Detector | Photo diode (320-1000 nm). |
| Blanking | Automatic zero setting. |
| Operator Interface | Membrane keyboard, for direct function and alpha-numeric entry Optional external keyboard High contrast graphical LCD display Real time clock, 24 hours system. |
| Measurement Procedures | Kinetic measurement with linearity check Kinetic, with linearity check and sample slope blank Two point kinetic, with or without reagent blank End point, with or without reagent blank Bichromatic end point, with or without reagent blank End point, with sample blank and with or without reagent blank. |
| Multiple Testing | Up to nine replicates Means, SD and CV. |
| Measurement Time | Programmable, 2 to 998 seconds for kinetic and two point type of tests For end point fixed at 2 seconds. |
| Delay Time | Programmable, 0 to 999 seconds. |
| Parameter Setting | Method name Measurement mode Wavelength 1 and 2 Aspiration volume Measurement delay Measurement time Factor Concentration standards Reagent blank y/n Sample blank y/n Units for results Levels for flagging Curve fit y/n Linearity check. |
| Calibration | Factor, one-point, two-point and multi-point Automatic on 1 standard (linear mode) Automatic on up to 10 standards (non-linear mode). |
| Quality Control | Two controls per test QC survey of last 30 control measurements Levey Jenning plot High/low flags. |
| Flowcell | Metal, with quartz windows, measuring volume 30 µL. |
| Temperature Control | By means of Peltier elements Fixed temperature at 37°C. |
| Aspirator System | Internal pump of bellows type, driven by stepper motor: Back panel connection for waste Aspiration volume programmable. |
| Printer | Internal matrix printer Normal paper External printer port available. |
| Signal Interface | Centronics type parallel port RS 232 type serial port PS 2 type port for external keyboard. |
| Standards and Regulations | CE -IVD CB UL. |
| Dimensions and Power Requirements | 40 x 17 x 36,6 cm (W x H x D) Weight: 8,5 kg. 100-240 VAC nominal, 50/60 Hz Battery back-up to retain data |
Mindray BA-88A
Rated 0 out of 5
In stock
SKU:
PGA-MINDRAYBA
| Principles | ALT, AST, ALP, ACP, GGT, α-HBDH, LDH, CK, AMY.TG.TC, HDL-C, UA, UREA, Cr, Glu, TP, Alb, T-bil, D-Bil, TBA, NH4+ , HCO3-, Ca, Mg, Cl , Na, K, apoAI , apoB, Lp ( a ), C3, C4 , lgG, lgA, lgM, HbA1c, Alcohol, Amphetamines, Barbiturates, Benzodiazepine etc . |
|---|---|
| Analysis Method | Endpoint , with or without reagent blank Endpoint , with sample blank and reagent blank Kinetics , with or without reagent blank Two-point Kinetics/Fixed-time , with or without reagent blank Absorbance Turbidimetry Linear and non-linear calibration |
| Light Source | Tungsten-halogen Iamp 6V/10W |
| Wavelength Range | Automatic by 8-position lter wheel 8 standard lters : 340nm , 405nm , 450nm , 510nm , 546nm , 578nm , 630nm and 670nm . Bandwidth < 8nm Stray light : < 0 . 1 % @ 340nm |
| Photometric Range | 0~3.5 ABS Stability : < 0 . 005A / 20min @ 340nm |
| Flowcell | Stainless steel with quartz window Measuring volume : 32 µL Optical path : 10mm Aspiration volume programmable : 200~9000 µL |
| Input | Touch screen with touch pen and popup keypad Mouse or Keyboard via USB |
| Temperature Control | By means of Peltier elements Room temperature , 25°C , 30 °C and 37°C |
| Storage | More than 3000 sample results More than 1000 QC results |
| Printer | Built-in thermal printer Supp |
| Interface | RS232 serial port supporting data transmission USB port (2. 0) for keyboard , mouse , printer |
| Operating Environment | Temperature : 15°C~30°C Humidity : 35% ~85%, no condensation |
| Power Requirement | Wide power supply : AC 100-240V, 50 / 60Hz |
| Dimension | 430mm x 360mm x 170mm ( L x W x H ) |
| Weight | 6.8 Kg |
Rayto RT-1904C
Rated 0 out of 5
In stock
SKU:
PGA-RAYTO1904C
| Photometric Range | 0,500 – 3,000Abs |
|---|---|
| Resolution | 0,001 Abs (displayed), 0,0001 Abs (calculated) |
| Light Source | Halogen lamp, 6V/10W |
| Wavelength Accuracy | ± 1 nm |
| Band width | 8 nm |
| Aspirate Volume | 100 – 3000 ul |
| Cross Contamination Rate | < 0,1% |
| Memory | 160 test protocols, minimum 1000 test result |
| Interface | RS-232, LAN Connector |
| Flow Cell | 25 ul Metal-quartz flow cell |
| Cuvette Mode | 12,5 mm x 12,5 mm cuvette optional |
| Temperature Control | 25º C, 30º C, 37º C, ±0,1º c |
| Display | 7″ color LCD |
| Input | Mouse and Optional external keyboard |
| Weight | 6.8 Kg |
| Output | Built-in printer or external printer (optional), SD Card |
| Net Weight | 8 Kg |
| Dimensions | L x W x H (mm) : 460 x 330 x 140 |
| Power Supply | AC 110V-220V ± 10%, 50-60 Hz |
Wap Lab WP-9200
Rated 0 out of 5
In stock
SKU:
PGA-WP9200
| Absorbance Range | 0.500 – 3.000 Abs |
|---|---|
| Resolution | 0.001 Abs (displayed), 0.0001 Abs (calculated) |
| Light Source | Halogen Lamp |
| Wavelength Accuracy | 340, 405, 500, 546, 620nm, 3 more filters optional ± 1nm |
| Band width | < 8nm |
| Aspirate Volume | 100 – 3000 ul |
| Cross Contamination Rate | < 1% |
| Interface | RA-232 serial cable |
| Flow Cell | Metal – quartz flow cell |
| Temperature Control | 25˚C, 30˚C, 37˚C, ± 0.1˚C and ambient temperature |
| Display | LCD display |
| Output | Internal printer or external printer (optional) |
| Net Weight | 7 KG |
| Dimensions | L x W x H (mm) : 360 x 318 x 160 |
| Power Supply | AC 100V – 240 ± 10%, 50-60 Hz |