Showing all 5 results
ELITech
Microlab 300
Rated 0 out of 5
In stock
SKU:
PGA-MICROLAB300
| Light Source | Quartz-iodine lamp 12V-20W. |
|---|---|
| Wavelength Range | Optical unit with 12 position filter wheel 340, 405, 505, 546, 578, 620 nm standard installed 6 positions for optional filters. |
| Photometric Range | 0.1 to 2.3 Absorbance Resolution 0.001 Abs. |
| Detector | Photo diode (320-1000 nm). |
| Blanking | Automatic zero setting. |
| Operator Interface | Membrane keyboard, for direct function and alpha-numeric entry Optional external keyboard High contrast graphical LCD display Real time clock, 24 hours system. |
| Measurement Procedures | Kinetic measurement with linearity check Kinetic, with linearity check and sample slope blank Two point kinetic, with or without reagent blank End point, with or without reagent blank Bichromatic end point, with or without reagent blank End point, with sample blank and with or without reagent blank. |
| Multiple Testing | Up to nine replicates Means, SD and CV. |
| Measurement Time | Programmable, 2 to 998 seconds for kinetic and two point type of tests For end point fixed at 2 seconds. |
| Delay Time | Programmable, 0 to 999 seconds. |
| Parameter Setting | Method name Measurement mode Wavelength 1 and 2 Aspiration volume Measurement delay Measurement time Factor Concentration standards Reagent blank y/n Sample blank y/n Units for results Levels for flagging Curve fit y/n Linearity check. |
| Calibration | Factor, one-point, two-point and multi-point Automatic on 1 standard (linear mode) Automatic on up to 10 standards (non-linear mode). |
| Quality Control | Two controls per test QC survey of last 30 control measurements Levey Jenning plot High/low flags. |
| Flowcell | Metal, with quartz windows, measuring volume 30 µL. |
| Temperature Control | By means of Peltier elements Fixed temperature at 37°C. |
| Aspirator System | Internal pump of bellows type, driven by stepper motor: Back panel connection for waste Aspiration volume programmable. |
| Printer | Internal matrix printer Normal paper External printer port available. |
| Signal Interface | Centronics type parallel port RS 232 type serial port PS 2 type port for external keyboard. |
| Standards and Regulations | CE -IVD CB UL. |
| Dimensions and Power Requirements | 40 x 17 x 36,6 cm (W x H x D) Weight: 8,5 kg. 100-240 VAC nominal, 50/60 Hz Battery back-up to retain data |
Selectra Pro M
Rated 0 out of 5
In stock
SKU:
PGA-SELECTRAPRO-M
| Kecepatan | Sampai dengan 266 tes per jam Sampai dengan 180 tes per jam pada mode MONO |
|---|---|
| Sumber Cahaya | Lampu Quartz-iodine 12V-20W |
| Fotometrik | Absorbansi – 0.1 hingga 3.0; Resolusi 0,001 Abs. |
| Konsumsi Air | Maksimal ~500 ml per jam, dengan operasi terus menerus |
| Standard dan Regulasi | ce-ivD cb |
| Dimensi | 122 x 75 x 61 cm (P x T x L) |
| Berat | 95kg |
| Antarmuka | Host: RS232 atau Etherhet (TCP/IP) melalui protokol LIS-2A. |
Selectra Pro XL
Rated 0 out of 5
In stock
SKU:
PGA-SELECTRAPRO-XL
| Throughput | Up to 450 photometric and electrolyte tests/hour. |
|---|---|
| Reagent System | 64 refrigerated reagent positions for 10 mL, 25 mL and 50 mL reagent bottles Cooled to 10°C +/- 4°C at normal laboratory conditions All reagent positions can be assigned as R1, R2 and R3. |
| Sample System | 80 barcode readable positions All positions fit 13×75 or 16x 100mm primary and secondary tubes and pediatric cups All positions can be used for calibrators, controls, normal, pediatric and STAT samples |
| Pipetting System | 1000 µL reagent syringe: R1 volume 110-400 µL R2 volume 0-180 µL R3 volume 0-180 µL Programmable in 1 µL steps 100 µL sample syringe: Sample volume 1-30 µL Programmable in 0.1 µL steps Pre programmed ratio selectable from ratios 1:2 up to 1:100 with 3 diluents Pre-heated probe with level detection, collision protection and integrated mixer. |
| Cuvette Rotor | Cost effective, semi-disposable cuvette rotor with 48 cuvettes Up to 10.000 tests per rotor Typical reagent consumption 220 µL per test Measurement temperature 37°C, controlled by Peltier elements. |
| Light Source | Quartz-iodine lamp 12V-20W |
| Wavelength Range | Optical unit with 8 position filter wheel 340, 405, 505, 546, 578, 620, 660, 700 nm standard wavelengths Other wavelengths available on request. |
| Photometric Range | -0.1 to 3.0 Absorbance Resolution 0.001 Abs. |
| Analytical Modes (Single, Dual and Triple reagent system) | Kinetic measurement with linearity check Mono- and bichromatic end point measurement with or without bichromatic reagent blank and/or sample blank correction Two point measurement; with or without slope blank Graphic plot of all measuring points Predilution and automatic reflex dilution as needed Range of calibration models Non-linear calibration curves Prozone check for immunology tests Cut-off declaration Calculated tests. |
| Quality Control | Up to 15 controls can be defined, 3 per test Westgard or Basic QC rules Levey-Jennings plots Quality control statistics. |
| Standards and Regulations | CE -IVD CB UL. |
| Dimensions | 117 x 115 x 80 cm (W x H x D) 46.1 x 45.3 x 31.5 in(W x H x D) |
| Weight | 190 kg (419 lbs). |
| Interface | Host-Query interface available Host: RS 232 or Ethernet (TCP/IP) through LIS-2A protocol. |
| Environmental Conditions | Temperature: 15 – 32 °C (59 – 90 °F) Humidity: 15 – 88% RH Altitude: up to 2000 m Plumbing: No dedicated water or drain required Electrical: Voltage: 100 – 240 Vac Frequency: 50 – 60 Hz Power (max): 380 VA . |
| Integrated PC | Touch screen navigation Operating system: Windowsâ„¢ XP |
| Barcode Reader | Hand held CCD barcode reader used for reagent identification |
| Eco Kit | Enables separate collection of concentrated measurement mixture and dilute (wash) waste |
| Dry ISE Module | Patented Solid State Electrode Technology Indirect measurement Dilution 1:14 Measures Sodium, Potassium, Chloride and CO2. |
| Positive Sample Identification | Positive Sample Identification (PSID) reads all popular barcodes. |
| Printer | Printer supported by MS Windowsâ„¢. |
| ProActive Maintenance Kit | Complete parts kit for annual preventive maintenance. |
Selectra Pro XS
Rated 0 out of 5
In stock
SKU:
PGA-SELECTRAPRO-XS
| Throughput | Up to 75 tests per hour. |
|---|---|
| Reagent System | Inner rotor ring: 15 reagent positions for 10 ml, 25 ml and 50 ml reagent bottles Optionally cooled to 10°C +/ 4°C at normal laboratory conditions. Outer rotor ring: 25 positions for (STAT) samples, controls and calibrators 15 positions for reagent bottles All positions fit 13×75 mm primary and secondary tubes and pediatric cups All positions can be used for calibrators, controls, normal, pediatric and STAT samples. |
| Pipetting System | 100 μl reagent syringe: – R1 volume 110-400 μl – R2 volume 0-180 μl -R3 volume 0-180 μl – Programmable in 1 μl steps 100 μl sample syringe: – Sample volume 1-30 μl – Programmable in 0.1 μl steps – Programmable dilution ratios 1:5 up to 1:100 in one step increments with 3 possible diluents Pre-heated probe with level detection, collision protection and integrated mixer. |
| Cuvette Rotor | Disposable cuvette rotor with 48 cuvettes Minimum measurement volume 220 μl Measurement temperature 37°C, controlled by Peltier elements. |
| Light Source | Quartz-iodine lamp 12V-20W. Wavelength Range Optical unit with 8 position filter wheel Automatic wavelength selection 340, 405, 505, 546, 578, 620, 660 nm standard installed One free position Other wavelenghts available on request. |
| Photometric Range | -0.1 to 3.0 Absorbance Resolution 0.001 Abs. |
| Analytical Modes (Single, Dual and Triple reagent system) | Kinetic measurement with linearity check Mono and bichromatic end point measurement with or without bichromatic reagent blank and/or sample blank correction Two point measurement; with or without slope blank Graphic plot of all measuring points Automatic rerun with sample reduction Non-linear calibration curves Prozone check for immunology tests Cut-off declaration Calculated tests. |
| Quality Control | Up to 15 different controls can be defined, 3 per test Westgard rules Levey-Jennings plots Quality control statistics. |
| Standards and Regulations | CE -IVD CB. |
| Dimensions | 89 x 58 x 60 cm (W x H x D) No peripherals |
| Weight | 67 kg. |
| Interface | State of the art Host-Query interface available Host: RS 232 or Ethernet (TCP/IP) through LIS-2A protocol. |
| Environmental Conditions | Temperature: 15 – 32 °C Humidity: 15 – 85% RH Altitude: up to 2,000 m Plumbing: No dedicated water or drain required Electrical: – Voltage: 100 – 240 Vac – Frequency: 50 – 60 Hz – Power (max): 350 VA . |
| Barcode Reader | Hand held CCD bar code reader used for test requisition, reagent identification and automated programing of assays, controls, and calibrators. |
| Printer | Printer supported by MS Windowsâ„¢ |
| ProActive Maintenance Kit | Complete parts kit for annual preventive maintenance. |