Showing 1–12 of 25 results

Hematology

DIRUI BCC-3600

In stock

SKU: PGA-DIRUIBCC3600
ParameterWBC, RBC, HGB, MCV, MCH, MCHC, HCT, PLT, NEUT#, MXD#. LYM#, NEUT%, MXD%, LYM%, RDW-CV, RDW-SD, PDW, MPV, PCT, P-LCR, PLCC
HistogramWBC, RBC, PLT
PrinciplesWBC, RBC, PLT: electrical impedance HGB: cyanide-free colorimetri
Cross ContaminationWBC, RBC, HGB<0.5%, PLT<1%
Aparture DiameterWBC 100 µm, RBC/PLT 70µm
Sample ConsumtionWhole blood 6 µL, Pre diluted blood 20µL
Throughput60 samples/ hour
Display10.2 inch touch screen, Resolution: 1024 X 600
ReagentDetergent, Diluent, BCC-3600 Lyse
Multiply QC MethodL-J, X : 12QC files, 30 result/file 16 : X-B: 1 file, 150 result/file
CalibrationManual calibration, automatic calibration, fresh blood calibration
Counting modewhole blood and pre -diluted blood
Input/OutputBuild in thermal printer, RS232, USB
Environment RequirementAmbient temperature 18⁰C-30⁰C, Relative humidity ≤75%
Power Supply100-240 VAC 50/60 HZ
Dimension (mm)430 (L) x 395 (W) x 432 (H)
Weight25 Kg

Hemaray 51

In stock

SKU: PGA-HEMARAY51
PrinciplesElectrical impedance, Colorimetry; Laser scattering method
ParametersWBC, BAS # BSA %, NEU # EOS # EOS %, LYM # LYM %, MON # MON %, RBC, HGB, HCT, MCV, KIA, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR, P-LCC; ALY # ALY %, LIC # LIC %; WBC Histogram, RBC Histogram, PLT Histogram; 2D DIFF Scatter gram x3; 3D DIFF Scatter gram x1;
Sample ConsumptionWhole blood 15ul (CBC+DIFF/CBC) Pre-diluted 20ul (CBC+DIFF/CBC)
Testing ModeCBC, CBC+DIFF
ReagentsRD-50 Diluent, RL-50D Iyse, RL-50H Iyse
Throughput60 s/h
Optional External DevicesBar-code reader, Mouse, Keyboard, External printer
Sample TypesWhole blood, peripheral whole blood, pre-diluted blood
SystemIntegrated windows system displayed by 10.4 inches color touch screen. Bi-directional LIS Communication
Working Environment10C ~ 30C; Humidity < 85%
Data Storage100000 results
Power110V-240V; 50Hz/60Hz; 400VA
PrinterInternal thermal printer
Size & WeightSize (mm) 365 x 470 x 525 Weight : 35Kg

Medonic M16/M20

In stock

SKU: PGA-MEDONICM16/M20
Reagen2 Jenis Reagen yang digunakan
Prinsip PengukuranWBC, RBC, PLT Impedansi
Prinsip Pengukuran HGBFotometer, metode bebas Cyanide 535 nm + 5nm HGB otomatis blank setiap sampel
WBC Diskriminator terprogramYa, diskriminator tersebar
Sistem SampelKatup geser tertutup
Sistem Diskriminator RBC/PLTYa
Sistem Analisis SampelOpen inlet dan PRE-Dilute
Volume Sampel darah open inlet / predilute<90ul/20ul
Pembacaan Sampel open inlet53 detik
Jumlah sampel/jam67 sampel
Parameter yang dilaporkan16 parameter : WBC, HGB, RBC, PLT, HCT, MCV, RDW, MPV, MCH, MCHC, LYM%, LYM, MID%, MID, GRAN%, GRAN RDW, PDW, PCT, LPCR
Parameter adapat di upgradeYa, 16 parameter menjadi 20 parameter, software tambahan.
Carry-overRBC, HGB, WBC<1% PLT <2%
CVWBC <1.8%, RBC <1.1%; MCV<0.3%; PLT<3.3%; HGB <1.0%
LCDBerwarna, layar sentuh TFT
Pembaca barcodeYa
PrinterEksternal, port tersedia
Bahasa SoftwareInggris, Indonesia, dll.
Serial OutputYa (sesuai standar EN 60950)
Tegangan230V fuse 5x20mm T1, 6A, 250V 120V fuse 5x20mm T3, 15A, 250V
Konsumsi ListrikMax 100VA Max 20VA (Standby)
Frekuensi50/60HZ
Temperatur18-32 C (64-90 F)
KelembabanHingga 80%
Dimensi, Berat, Sertifikat41x29x46cm (P x L x T) <18kg, versi standar ISO, CE, EMC, AKL-DEPKES

Medonic M32

In stock

SKU: PGA-MEDONICM32
Samples per hour60
No. of parameters20
Touch-screenColor
Samples memory50.000
QC softwareYes
No. of reagents used2
Time to result, open tube inlet<50 sec
Cv WBC:1.8%
Cv RBC:1.1%
Cv PLT:3.3%
Cv HGB:1.0%

Mindray BC 30

In stock

SKU: PGA-MIDNRAYBC30
PrinciplesImpedance method for WBC, RBC and PLT counting Cyanide free reagent for hemoglobin test
Parameters21 parameters: WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR,P-LCC 3 histograms for WBC, RBC and PLT
Sample VolumePrediluted mode ≤20μL Whole blood mode ≤9 μL
PerformanceParameter Linearity Range Precision (CV %) Carryover WBC(109/L) 0-300 ≤3.5% (4.0-6.9) ≤0.5% ≤2.0% (7.0-15.0) RBC(1012/L) 0-8.00 ≤1.5% (3.50-6.5) ≤0.5% HGB(g/L) 0-280 ≤1.5% (100-180) ≤0.5% MCV(fL) ≤0.5% (70.0-110.0) ≤0.5% PLT(109/L) 0-4000 ≤5.0% (100-149) ≤1.0% ≤4.0% (150-500)
Throughput60 samples per hour
Display10.4 inch TFT Touch Screen
Multi LanguageChinese, English, Spanish, Portuguese, Russian, French, Bahasa Indonesia
Data storage capacityUp to 400,000 results including numeric and graphical information
CommunicationLAN Port supports HL7 protocol Support bi-directional LIS
Interface4 USB ports (for external printer, software upgrade, barcode reader, external WIFI, keyboard and mouse), LAN port (1)
PrintoutThermal recorder, 50 mm wide paper, various printouts formats External printer optional
Power Requirement(100V-240V)±10% ≤180VA (50Hz/60Hz) ±1Hz
Dimension and WeightDimension: Depth (410 mm) x width (300 mm) x height (400 mm) Weight: ≤20Kg

Mindray BC 30s

In stock

SKU: PGA-MIDNRAYBC30s
PrinciplesImpedance method for WBC, RBC and PLT counting Cyanide free reagent for hemoglobin test
Parameters21 parameters: WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR,P-LCC 3 histograms for WBC, RBC and PLT
ReagentM-30D DILUENT M-30CFL LYSE PROBE CLEANSER
Sample VolumePrediluted mode 20μL Whole blood mode 9 μL
PerformanceParameter Linearity Range Precision (CV %) Carryover WBC(109/L) 0-200 ≤3.5% (4.0-6.9) ≤0.5% ≤2.0% (7.0 -15.0) RBC(1012/L) 0-8.00 ≤1.5% (3.5-6.5) ≤0.5% HGB(g/L) 0-280 ≤1.5% (100 -180) ≤0.5% MCV(fL) ≤1.0% (70 -110) PLT(109/L) 0-4000 ≤5.0% (100 -149) ≤1.0% ≤4.0% (150 -500)
Throughput70 samples per hour
Display10.4 inch TFT Touch Screen
Multi LanguageChinese, English, Spanish, Portuguese, Russian, French, Bahasa Indonesia
Data storage capacityUp to 500,000 results including numeric and graphical information
CommunicationLAN Port supports HL7 protocol Support bi-directional LIS
Interface4 USB port (for external printer, software upgrade, barcode reader, WIFI adapter,keyboard and mouse), LAN port (1)
PrintoutThermal recorder, 50 mm wide paper, various printouts formats External printer optional
Operating EnvironmentTemperature: 10°C~40°C Humidity: 10%~90% Air pressure: 70kPa~106kPa
Power Requirement100V-240V ≤300VA 50Hz/60Hz
Dimension and WeightDimension: Depth(410 mm) x width(300 mm) x height(400 mm) Weight: ≤20Kg

Mindray BC 700 & BC 720

In stock

SKU: PGA-MIDNRAYBC700
PrinciplesWBC (IMG/Neu/Mon/Lym/Eos/Bas), NRBC/RET*,PLT-H/PLT-O*/IPF: SF Cube ^ Cell Analysis Technology ^S: Scatter; F: Fluorescence; Cube: 3D analysis
RBC, PLTFocusing Flow-DC Impedance Method
HGBColorimetric method
ESRPhotometric method
Number of measuring parameters (whole blood):109
Number of measuring parameters (body fluid):18
Number of reportable parameters:7 WBC-BF TC-BF# MN# MN% PMN# PMN% RBC-BF
Number of research parameters:11
Sample volumeCD (whole blood): 23ul CD+ESR (whole blood): 160ul Predilute: 20ul
Data storage capacityUp to 150,000 results including numeric and graphical information *
ThroughputCD 80t/h CDR 45t/h CD+ESR 40t/h
Whole bloodCBC, CBC + DIFF, CBC + DIFF + RET*, CD + ESR, CDR + ESR*, CD/WBC-3X, CDR/PLT-5X*, and other modes
PrediluteCBC, CBC + DIFF, CDR*, and other modes
Body fluidCBC + DIFF
Dimensions500D x 325W x 450H mm
Weight≤35Kg
Voltage100V-240V~ (±10%)
Frequency50Hz/60Hz (±1Hz)
Power input300VA
External outputLAN x 1 , USB x 4 (Specifications: DC 5V; 500mA; USB 2.0 x 3; USB 3.0 x 1)
Ambient temperature10℃ ~ 35℃
Relative humidity30% ~ 85%
Atmospheric pressure:70.0kPa ~ 106.0kPa^ ^Note : Required altitude for normal operation: -400m ~ +3000m
PerformanceParameter Linearity Range Precision Carryover WBC 0-500×10^9 /L ≤2.5% (≥4.51×10^9 /L) ≤ 1.0% RBC 0-8.60×10^12/L ≤1.5% (≥3.5×10^12/L) ≤ 1.0% HGB 0-260g/L ≤1.0% (110-180g/L) ≤ 1.0% HCT 0-75% ≤1.5% (30%-50%) ≤ 1.0% PLT* 0-5000×10^9 /L ≤ 1.5(SD) (≤20×10^9/L)^ ≤ 1.0% ≤ 2.5% (≥100×10^9/L)^ RET* 0-0.8×10^12/L ≤15% (RBC ≥ 3.00×10^12/L ≤ 1.0% RET%: 1.00% ~ 4.00%) ESR ≤1.8(SD)(0~20mm/h) ≤ 1.0% ^ Note: Applicable only to CDR/PLT-O 5x and CR/PLT-O 5x models Items marked with an asterisk (*) apply only to BC-720

Mindray BC 760 & BC 780

In stock

SKU: PGA-MIDNRAYBC760
PrinciplesWBC (IMG/Neu/Mon/Lym/Eos/Bas), NRBC/RET*,PLT-H/PLT-O*/IPF: SF Cube ^ Cell Analysis Technology ^S: Scatter; F: Fluorescence; Cube: 3D analysis
RBC, PLTFocusing Flow-DC Impedance Method
HGBColorimetric method
ESRPhotometric method
Number of measuring parameters (whole blood):109
Number of measuring parameters (body fluid):18
Number of reportable parameters:7 WBC-BF TC-BF# MN# MN% PMN# PMN% RBC-BF Number of research parameters: 11
Sample volumeCD (whole blood): 25ul CD+ESR (whole blood): 160ul Predilute: 20ul
Data storage capacityUp to 150,000 results including numeric and graphical information *
ThroughputCD 80t/h CDR 45t/h CD+ESR 40t/h
Whole bloodCBC, CBC + DIFF, CBC + DIFF + RET*, CD + ESR, CDR + ESR*, CD/WBC-3X, CDR/PLT-5X*, and other modes
PrediluteCBC, CBC + DIFF, CDR*, and other modes
Body fluidCBC + DIFF
Dimensions840D x 655W x 600H mm
Weight≤70.6Kg
Voltage100V-240V~ (±10%)
Frequency50Hz/60Hz (±1Hz)
Power input600VA
External outputLANx1 , USB x 4 (Specifications: DC 5V; 500mA; USB2.0 x 3; USB3.0 x 1 )
Ambient temperature10℃ ~ 35℃a
Relative humidity30% ~ 85%
Atmospheric pressure:70.0kPa ~ 106.0kPa^ ^Note : Required altitude for normal operation: -400m ~ +3000m
PerformanceParameter Linearity Range Precision Carryover WBC 0-500×10^9 /L ≤2.5% (≥4.51×10^9 /L) ≤ 1.0% RBC 0-8.60×10^12/L ≤1.5% (≥3.5×10^12/L) ≤ 1.0% HGB 0-260g/L ≤1.0% (110-180g/L) ≤ 1.0% HCT 0-75% ≤1.5% (30%-50%) ≤ 1.0% PLT* 0-5000×10^9 /L ≤ 1.5(SD) (≤20×10^9/L)^ ≤ 1.0% ≤ 2.5% (≥100×10^9/L)^ RET* 0-0.8×10^12/L ≤15% (RBC ≥ 3.00×10^12/L ≤ 1.0% RET%: 1.00% ~ 4.00%) ESR ≤1.8(SD)(0~20mm/h) ≤ 1.0% ^ Note: Applicable only to CDR/PLT-O 5x and CR/PLT-O 5x models Items marked with an asterisk (*) apply only to BC-720

Mindray BC-10

In stock

SKU: PGA-MIDNRAYBC10
PrinciplesImpedance method for WBC, RBC and PLT counting Cyanide free reagent for hemoglobin test
Parameters20 parameters: WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR 3 histograms for WBC, RBC and PLT
Sample VolumePrediluted mode ≤20μL Whole blood mode ≤9 μL
PerformanceParameter Linearity Range Precision (CV %) Carryover WBC(109/L) 0-100 ≤3.5% (4.0-6.9) ≤0.5% ≤2.0% (7.0-15.0) RBC(1012/L) 0-8.00 ≤2.0% (3.50-6.5) ≤0.5% HGB(g/L) 0-280 ≤2.0% (100-180) ≤0.5% MCV(fL) ≤1.0% (70.0-110.0) ≤0.5% PLT(109/L) 0-1000 ≤5.0% (100-500) ≤1.0%
Throughput30 samples per hour
Display8.4 inch TFT Touch Screen
Multi-languageChinese, English, Spanish, Portuguese, Russian, French, Bahasa Indonesia
Data Storage CapacityUp to 50,000 results including numeric and graphical information
CommunicationLAN Port supports HL7 protocol Support bi-directional LIS
Interface4 USB ports (for external printer, software upgrade, barcode reader, external WIFI, keyboard and mouse), LAN port (1)
PrintoutThermal recorder, 50 mm wide paper, various printouts formats
Power Requirement(100V-240V)±10% ≤180VA (50Hz/60Hz) ±1Hz
DimensionDepth (410 mm) x width (300 mm) x height (400 mm)
Weight≤20Kg

Mindray BC-11

In stock

SKU: PGA-MIDNRAYBC11
PrinciplesImpedance method for WBC, RBC and PLT counting Cyanide free reagent for hemoglobin test
Parameters20 parameters: WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR 3 histograms for WBC, RBC and PLT 2 research parameters: NLR, PLR
Sample VolumePrediluted mode ≤20μL Whole blood mode ≤9 μL
PerformanceParameter Linearity Range Precision (CV %) Carryover WBC(109/L) 0-100 ≤3.5% (4.0-6.9) ≤0.5% ≤2.0% (7.0-15.0) RBC(1012/L) 0-8.00 ≤2.0% (3.50-6.5) ≤0.5% HGB(g/L) 0-280 ≤2.0% (100-180) ≤0.5% MCV(fL) ≤1.0% (70.0-110.0) ≤0.5% PLT(109/L) 0-1000 ≤5.0% (100-500) ≤1.0%
Throughput30 samples per hour
Display8.4 inch TFT Touch Screen
Multi-languageChinese, English, Spanish, Portuguese, Russian, French, Bahasa Indonesia
Data Storage CapacityUp to 50,000 results including numeric and graphical information
CommunicationLAN Port supports HL7 protocol Support bi-directional LIS
Interface4 USB ports (for external printer, software upgrade, barcode reader, external WIFI, keyboard and mouse), LAN port (1)
PrintoutThermal recorder, 50 mm wide paper, various printouts formats
Power Requirement(100V-240V)±10% ≤180VA (50Hz/60Hz) ±1Hz Temperature: 15°C~30°C Humidity: 10%~90% Air pressure: 70kPa~106kPa
DimensionDepth (410 mm) x width (300 mm) x height (400 mm)
Weight≤20Kg

Mindray BC-2800

In stock

SKU: PGA-MIDNRAYBC2800
ParameterWBC, Lymph #, Mid #, Gran #, Lymph%, Mid%, Gran%, RBC, HGB, HCT, MCV, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT dan Histogram untuk WBC, RBC, PLT
PrinsipMetode impedansi listrik untuk penghitungan dan metode bebas sianida untuk hemoglobin.
KinerjaParameter Linearity Range Precision (CV%) WBC (10⁹ / L) 0,0-99.9 3 (4.0-15.0) RBC (10¹² / L) 0,0-9,99 2 (3,0-6,5) HGB (g / L) 0-300 2 (100-180) MCV (fL) 1 (70-100) PLT (10⁹ / L) 0-999 5 (200-500)
Volume ContohPrediluted 20 μL Seluruh Darah 13 μL
Diameter Lubang80 μm
Throughput30 sampel per jam
Time to result, open tube inlet<50 sec
DisplayLayar LCD berwarna Resolusi: 640 x 480
MenopangWBC, RBC, HGB≤0,5%, PLT≤1%
Input outputRS232 x 2, 1 printer paralel (opsional), pemindai kode 1 bar (opsional) 1 antarmuka keyboard
PrinterPerekam thermal, kertas lebar 50mm, banyak format cetakan, printer opsional
Lingkungan operasiSuhu: 15 ° C ~ 30 ° C Kelembaban: 30% ~ 85%
Kebutuhan dayaAC100-240V, 50 / 60Hz
Dimensi322 (W) x 437 (H) x 386 (D)
Berat17,9 Kg

Mindray BC-3000 Plus

In stock

SKU: PGA-MIDNRAYBC3000P
ParameterWBC, Lymph #, Mid #, Gran #, Lymph #, Mid%, Gran%, Lymph%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT dan Histogram untuk WBC, RBC, PLT
PrinsipMetode impedansi listrik untuk penghitungan dan metode bebas sianida untuk hemoglobin.
KinerjaParamter Linearity Range Precision (CV%) WBC (109 / L) 0,3-99,9 2,5 (7,0-15,0) RBC (1012 / L) 0. 20 – 8.00 2 (3,50 -6. 00) HGB (g / L) 10-250 1. 5 (110 -180) MCV (fL) 0. 5 (80,0-11 0,0) PLT (109 / L) 10-999 5 (150-500)
Volume ContohPrediluted 20 μL Seluruh Darah 13 μL
Diameter LubangWBC 100 µm RBC / PLT 70 µm
Throughput60 sampel per jam
DisplayLayar LCD warna besar Resolusi: 800 x 600 Alarm – 41 pesan kesalahan
MenopangWBC, RBC, HGB ≤ 0,5%, PLT ≤ 1%
Input outputRS232 x 2, 1 printer paralel (opsional), pemindai kode 1 bar (opsional) 1 antarmuka keyboard
PrinterThermaI recorde, kertas lebar 50 mm, banyak format cetakan, printer opsional
Lingkungan operasiSuhu 15 ° C ~ 30 ° C Kelembaban 30% ~ 85%
Kebutuhan dayaAC 100-240V, 50 / 60Hz
Dimensi390 (W) x 460 (H) x 400 (D)
Berat21 Kg