DIRUI BCC-3600
Rated 0 out of 5
In stock
SKU:
PGA-DIRUIBCC3600
| Parameter | WBC, RBC, HGB, MCV, MCH, MCHC, HCT, PLT, NEUT#, MXD#. LYM#, NEUT%, MXD%, LYM%, RDW-CV, RDW-SD, PDW, MPV, PCT, P-LCR, PLCC |
|---|---|
| Histogram | WBC, RBC, PLT |
| Principles | WBC, RBC, PLT: electrical impedance HGB: cyanide-free colorimetri |
| Cross Contamination | WBC, RBC, HGB<0.5%, PLT<1% |
| Aparture Diameter | WBC 100 µm, RBC/PLT 70µm |
| Sample Consumtion | Whole blood 6 µL, Pre diluted blood 20µL |
| Throughput | 60 samples/ hour |
| Display | 10.2 inch touch screen, Resolution: 1024 X 600 |
| Reagent | Detergent, Diluent, BCC-3600 Lyse |
| Multiply QC Method | L-J, X : 12QC files, 30 result/file 16 : X-B: 1 file, 150 result/file |
| Calibration | Manual calibration, automatic calibration, fresh blood calibration |
| Counting mode | whole blood and pre -diluted blood |
| Input/Output | Build in thermal printer, RS232, USB |
| Environment Requirement | Ambient temperature 18⁰C-30⁰C, Relative humidity ≤75% |
| Power Supply | 100-240 VAC 50/60 HZ |
| Dimension (mm) | 430 (L) x 395 (W) x 432 (H) |
| Weight | 25 Kg |
ESR Analyzer Caretium XC-A30
Rated 0 out of 5
In stock
SKU:
PGA-CARETIUMXC
| Prinsip pengukuran | Pemblokiran garis luar |
|---|---|
| Akurasi pengukuran | <0.2mm |
| Residual Volume | <1 µL |
| Pada saat yang sama dapat mengukur jumlah sampel | 30 |
| Waktu pengukuran | 30min / 60min opsional |
| Volume sampel | 1,6 ml darah utuh antikoagulan |
| Kondisi kerja | Suhu 15 ° C ~ 32oC, suhu relatif: 45% ~ 85% |
| Sumber Daya | AC 220V ± 10% 50Hz |
| Antarmuka Data | RS-232 |
| Volume | 400mm × 300mm × 180mm |
| Berat | 10 kg |
Glory 127
Rated 0 out of 5
In stock
SKU:
PGA-GLORY127
| Reading Cuvette | Both flow through cell and direct reading cuvette |
|---|---|
| Photometric System | Light Source 6V/10W halogen lamp |
| Wavelength | 340/405/492/510/546/578/620nm, 2 more filter on request |
| Wavelength Accuracy | 2nm |
| Thermostatic Control | Temperatur 25C, 30C, 37C, Precision 2nm |
| Measuring System | Method : End Point, Fixed Time, Multistandart, Differential, Bichromatic and Immunoturbidimetric. |
| Measuring Range | 0-3.000 O.D |
| Photometric Linearity | 2% (0-3.000 O.D) |
| Photometeric Accuracy | 1% (0-3.000 O.D) |
| Storage | Over 200 programs, 1000 test result |
| Incubator | 20 incubating positions |
| Display | Black-illuminated LCD |
| Printer | Built in thermal printer |
| Interface | RS-232 Serial port for additional PC, USB port on request |
| Power Supply | AC110V / 60Hz or 220V / 50Hz |
| Dimensions | 340mm, 380mm, 180mm |
| Weight | 8.0 Kg |
Glory 917
Rated 0 out of 5
In stock
SKU:
PGA-GLORY917-2024
| Machine type | Random access, open reagent & locked reagent (optional) |
|---|---|
| Test Speed | Constant 150 tests/hour (Mono reagent or double reagent) |
| Test Principle | Colorimetric method, turbidimetry |
| Test Method | 1 point end, 2 point end, Fixed-Time, Kinetics |
| Calibration Type | Linear & nonlinear |
| Sample Tray | 40 sample positions |
| Sample Tube | Micro cup & test tube & blood collection tube can be used. ( Φ 12 -13 )mm * ( 25 – 100 ) mm |
| Sample Volume | 2-30μL, step by 0.1μL |
| Sample Probe | Liquid surface detection, timely tracking for liquid volume. Collision avoidance |
| Sample Barcode | Sample barcode reader (optional) |
| Reagent Tray | 80 reagent positions (40 for R1 & 40 for R2), Non-stop cooling system with peltier pad inside, 24 hours 2°C-14°C, open system, could accept any reagent. |
| Reagent Volume | 20-300μl, step by 1μl |
| Reagent Needle | Liquid surface detection, timely tracking for liquid volume. Collision avoidance. |
| Regent Barcode | Regent barcode reader (optional) |
| Reaction tray | 44 reaction cuvettes, new amorphous optical plastics reaction cups, perfect transmittance. |
| Reaction Volume | 150μl-330μl |
| Reaction Time | 10 minutes |
| Temperature | Peltier pad incubation system, reaction temperature (37℃ ± 0.1℃) |
| Mixer | Paddle-type mixing, effective reducing of carry-over |
| Light Source | Halogen lamp |
| Wavelength | 340nm; 405nm; 450nm; 505nm; 546nm; 578nm; 630nm; 700nm(4 more options) |
| Absorbance range | 0-4.0 Abs |
| Resolution | 0.0001 Abs |
| Operation System | Windows XP, Windows 7, Windows 8, Windows 10 |
| Data Processing | Automatic calibration, test combination, effective time management of reagents, serum index, whole process detection, linear expansion of enzyme, blank deduction,dirty cuvette memory , cross infection prevention, patient information memory and association input, automatic report audit, data fuzzy query, report statistics and printing, reference range grading, alarm information classification, user operation privilege classification management. |
| Report Printing | 6 formats optional, surpport custom pattern |
| Interface | TCP/IP network interface |
| Power Supply | AC 110/220V ± 10%, 50/60 Hz, 650W |
| Water Consumption | 6L/hour(maximum) |
| Dimension | 750mm * 560mm * 535mm(L*W*H) |
| Weight | 52 kg |
HBC-150 Haier
Rated 0 out of 5
In stock
SKU:
PGA-KVHHBC150-HAIER
| Cabinet Type | Chest |
|---|---|
| Ambient Temperature (C) | 5-43 |
| Cooling Type | Direct Cooling |
| Refrigerant | HC |
| Sound Level (dB(A)) | <40 |
| Temperature Range (C) | 2-8 |
| Freezer Protection Level | A |
| Controller | Microprocessor |
| Display | Solar LED Temperature Display |
| Power Supply (V) | 220-240/50 |
| Power (W) | 120 |
| Electrical Current (A) | 1 |
| Power Consumption: Stable Running (KWh/24h) | 0.54 |
| Power Consumption: Cool Down Test (KWh/24h) | 0.62 |
| Holdover Time at 43°C | 60hrs 50mins |
| Holdover Time at 32°C | 96hrs 23mins |
| Vaccine Storage Capacity (L/Cu.Ft) | 122/4.3 |
| Gross Volume (L/Cu.Ft) | 150/5.3 |
| Net/Gross Weight (approx) | 105/140 kg 231.7/308.9 lbs |
| Interior Dimensions (W*D*H) | 840*366*560 mm 33.1*14.4*22 in |
| Exterior Dimensions (W*D*H) | 1128*717*872 mm 44.4*28.2*34.3 in |
| Packing Dimensions (W*D*H) | 1190*770*1080 mm 47*30*42.5 in |
| Container Load (20'/40'/40'H) | 26/56/56 |
| High/Low Temperature | Y |
| Sensor Error | Y |
| Foot/Castor | N |
| Baskets | 3 |
| Data Logger | Y |
| Automatic Voltage Stabilizer | Optional |
| Remote Temperature Monitoring Device (RTMD) | Optional |
| Certification | CE, WHO/PQS |