Showing 1–12 of 13 results
Alat Kimia Klinik adalah instrumen yang digunakan dalam laboratorium medis untuk menganalisis sampel biologis seperti darah, urin, dan cairan tubuh lainnya.
Tujuan utama dari alat kimia klinik ini adalah membantu dalam diagnosis, pemantauan, dan penelitian berbagai kondisi kesehatan, termasuk penyakit metabolik, infeksi, serta gangguan organ tubuh.
Alat Kimia Klinik
Chempro 3.0
Rated 0 out of 5
In stock
SKU:
PGA-CHEMPRO3.0
| Detection Method | Photometric detection |
|---|---|
| Detection time | <3mins |
| CV | <10% |
| Sample Type | Serum, whole blood, plasma |
| Sample volume | 45uL |
| Power supply | Adapter input AC100~240V,50/60Hz, 30VA: Output 5V,2A |
| Built-in Lithium battery | DC 3.7 +- 0.3V |
| Measurement | 157.5*145.7*64.6mm |
| Weight | 622g |
| Data storage | 3000 results |
| Display | 4.3′ touch screen |
| Storage environment | Temp 20C ~ 60C; Rh: 10% ~ 90% |
| Operation environment | Temp 15C ~ 35C; Rh:<85% |
Chemray 120
Rated 0 out of 5
In stock
SKU:
PGA-CHEMRAY120
| Throughput | Lebih dari 100 test / jam. |
|---|---|
| Konten Pengujian | Clinical Chemistry, Immunoturbidimetric. |
| Mode Analisa | End-point, Two-point, Kinetic. |
| Programming | Open system with user defined programs. |
| Otomatis | Akses Acak. |
| Posisi Sampel | 9 posisi untuk sampel. |
| Ukuran Sampel | 3 ~ 45 uL, 0,5 uL adjustable. |
| Posisi Reagent | 26 Posisi untuk Reagent. |
| Ukuran Reagent | R1 : 180 ~ 450 uL, 1 uL adjustable. R2 : 3 ~ 450 uL, 1 uL adjustable. |
| Posisi Reaksi | 90 cuvettes, 10 cuvettes/strip. |
| Cuvette | Optical Length 5mm. |
| Ukuran Reaksi | 180 ~ 500ul. |
| Temperatur Reaksi | 37C, Fluctuation 0.3C. |
| Print Out | Built in thermal printer, external printer optional. |
Chemray 240
Rated 0 out of 5
In stock
SKU:
PGA-CHEMRAY240
| Throughput | Lebih dari 160 test / jam. |
|---|---|
| Konten Pengujian | Clinical Chemistry, Immunoturbidimetric. |
| Mode Analisa | End-point, Two-point, Kinetic. |
| Programming | Open system with user defined programs. |
| Otomatis | Akses Acak. |
| Posisi Sampel | 40 posisi untuk sampel. |
| Ukuran Sampel | 3 ~ 100 uL, 0,5 uL adjustable. |
| Posisi Reagent | 40 Posisi untuk Reagent. Refrigerated Temperatre : 16C |
| Ukuran Reagent | R1 : 180 ~ 450 uL, 1 uL adjustable. R2 : 30 ~ 450 uL, 1 uL adjustable. |
| Posisi Reaksi | 81 cuvettes, 9 cuvettes/strip. |
| Cuvette | 8 Step Washer System. |
| Ukuran Reaksi | 180 ~ 500ul. |
| Temperatur Reaksi | 37C, Fluctuation 0.2C. |
Glory 917
Rated 0 out of 5
In stock
SKU:
PGA-GLORY917-2024
| Machine type | Random access, open reagent & locked reagent (optional) |
|---|---|
| Test Speed | Constant 150 tests/hour (Mono reagent or double reagent) |
| Test Principle | Colorimetric method, turbidimetry |
| Test Method | 1 point end, 2 point end, Fixed-Time, Kinetics |
| Calibration Type | Linear & nonlinear |
| Sample Tray | 40 sample positions |
| Sample Tube | Micro cup & test tube & blood collection tube can be used. ( Φ 12 -13 )mm * ( 25 – 100 ) mm |
| Sample Volume | 2-30μL, step by 0.1μL |
| Sample Probe | Liquid surface detection, timely tracking for liquid volume. Collision avoidance |
| Sample Barcode | Sample barcode reader (optional) |
| Reagent Tray | 80 reagent positions (40 for R1 & 40 for R2), Non-stop cooling system with peltier pad inside, 24 hours 2°C-14°C, open system, could accept any reagent. |
| Reagent Volume | 20-300μl, step by 1μl |
| Reagent Needle | Liquid surface detection, timely tracking for liquid volume. Collision avoidance. |
| Regent Barcode | Regent barcode reader (optional) |
| Reaction tray | 44 reaction cuvettes, new amorphous optical plastics reaction cups, perfect transmittance. |
| Reaction Volume | 150μl-330μl |
| Reaction Time | 10 minutes |
| Temperature | Peltier pad incubation system, reaction temperature (37℃ ± 0.1℃) |
| Mixer | Paddle-type mixing, effective reducing of carry-over |
| Light Source | Halogen lamp |
| Wavelength | 340nm; 405nm; 450nm; 505nm; 546nm; 578nm; 630nm; 700nm(4 more options) |
| Absorbance range | 0-4.0 Abs |
| Resolution | 0.0001 Abs |
| Operation System | Windows XP, Windows 7, Windows 8, Windows 10 |
| Data Processing | Automatic calibration, test combination, effective time management of reagents, serum index, whole process detection, linear expansion of enzyme, blank deduction,dirty cuvette memory , cross infection prevention, patient information memory and association input, automatic report audit, data fuzzy query, report statistics and printing, reference range grading, alarm information classification, user operation privilege classification management. |
| Report Printing | 6 formats optional, surpport custom pattern |
| Interface | TCP/IP network interface |
| Power Supply | AC 110/220V ± 10%, 50/60 Hz, 650W |
| Water Consumption | 6L/hour(maximum) |
| Dimension | 750mm * 560mm * 535mm(L*W*H) |
| Weight | 52 kg |
PUSHKANG MS100
Rated 0 out of 5
In stock
SKU:
PGA-PUSHKANGMS100
| Sample type | Anticoagulant whole blood, plasma, serum, capillary blood |
|---|---|
| Test principle | Photoelectric colorimetry |
| Connection | On-line of LIS system |
| Sample Volume | 140μL |
| Test time | ≦15min |
| Code identification | Automatic identification of QR code for reagent disc |
| Reagent type | Lyophilized reagent |
| Light source | LED lamp |
| Printer | Built-in thermal printer and external printer (wireless printer driver) |
| Operating system | Android 5.1 (5-inch) |
| Memory capacity | 1GB, with expandable 32GB TF card |
| Supply voltage | AC 100V-240V, 50-60HZ |
| Size | 270mm*180mm*155mm |
| Weight | 3 KG, with built-in adapter |
Selectra Pro M
Rated 0 out of 5
In stock
SKU:
PGA-SELECTRAPRO-M
| Kecepatan | Sampai dengan 266 tes per jam Sampai dengan 180 tes per jam pada mode MONO |
|---|---|
| Sumber Cahaya | Lampu Quartz-iodine 12V-20W |
| Fotometrik | Absorbansi – 0.1 hingga 3.0; Resolusi 0,001 Abs. |
| Konsumsi Air | Maksimal ~500 ml per jam, dengan operasi terus menerus |
| Standard dan Regulasi | ce-ivD cb |
| Dimensi | 122 x 75 x 61 cm (P x T x L) |
| Berat | 95kg |
| Antarmuka | Host: RS232 atau Etherhet (TCP/IP) melalui protokol LIS-2A. |
Selectra Pro XL
Rated 0 out of 5
In stock
SKU:
PGA-SELECTRAPRO-XL
| Throughput | Up to 450 photometric and electrolyte tests/hour. |
|---|---|
| Reagent System | 64 refrigerated reagent positions for 10 mL, 25 mL and 50 mL reagent bottles Cooled to 10°C +/- 4°C at normal laboratory conditions All reagent positions can be assigned as R1, R2 and R3. |
| Sample System | 80 barcode readable positions All positions fit 13×75 or 16x 100mm primary and secondary tubes and pediatric cups All positions can be used for calibrators, controls, normal, pediatric and STAT samples |
| Pipetting System | 1000 µL reagent syringe: R1 volume 110-400 µL R2 volume 0-180 µL R3 volume 0-180 µL Programmable in 1 µL steps 100 µL sample syringe: Sample volume 1-30 µL Programmable in 0.1 µL steps Pre programmed ratio selectable from ratios 1:2 up to 1:100 with 3 diluents Pre-heated probe with level detection, collision protection and integrated mixer. |
| Cuvette Rotor | Cost effective, semi-disposable cuvette rotor with 48 cuvettes Up to 10.000 tests per rotor Typical reagent consumption 220 µL per test Measurement temperature 37°C, controlled by Peltier elements. |
| Light Source | Quartz-iodine lamp 12V-20W |
| Wavelength Range | Optical unit with 8 position filter wheel 340, 405, 505, 546, 578, 620, 660, 700 nm standard wavelengths Other wavelengths available on request. |
| Photometric Range | -0.1 to 3.0 Absorbance Resolution 0.001 Abs. |
| Analytical Modes (Single, Dual and Triple reagent system) | Kinetic measurement with linearity check Mono- and bichromatic end point measurement with or without bichromatic reagent blank and/or sample blank correction Two point measurement; with or without slope blank Graphic plot of all measuring points Predilution and automatic reflex dilution as needed Range of calibration models Non-linear calibration curves Prozone check for immunology tests Cut-off declaration Calculated tests. |
| Quality Control | Up to 15 controls can be defined, 3 per test Westgard or Basic QC rules Levey-Jennings plots Quality control statistics. |
| Standards and Regulations | CE -IVD CB UL. |
| Dimensions | 117 x 115 x 80 cm (W x H x D) 46.1 x 45.3 x 31.5 in(W x H x D) |
| Weight | 190 kg (419 lbs). |
| Interface | Host-Query interface available Host: RS 232 or Ethernet (TCP/IP) through LIS-2A protocol. |
| Environmental Conditions | Temperature: 15 – 32 °C (59 – 90 °F) Humidity: 15 – 88% RH Altitude: up to 2000 m Plumbing: No dedicated water or drain required Electrical: Voltage: 100 – 240 Vac Frequency: 50 – 60 Hz Power (max): 380 VA . |
| Integrated PC | Touch screen navigation Operating system: Windowsâ„¢ XP |
| Barcode Reader | Hand held CCD barcode reader used for reagent identification |
| Eco Kit | Enables separate collection of concentrated measurement mixture and dilute (wash) waste |
| Dry ISE Module | Patented Solid State Electrode Technology Indirect measurement Dilution 1:14 Measures Sodium, Potassium, Chloride and CO2. |
| Positive Sample Identification | Positive Sample Identification (PSID) reads all popular barcodes. |
| Printer | Printer supported by MS Windowsâ„¢. |
| ProActive Maintenance Kit | Complete parts kit for annual preventive maintenance. |
Selectra Pro XS
Rated 0 out of 5
In stock
SKU:
PGA-SELECTRAPRO-XS
| Throughput | Up to 75 tests per hour. |
|---|---|
| Reagent System | Inner rotor ring: 15 reagent positions for 10 ml, 25 ml and 50 ml reagent bottles Optionally cooled to 10°C +/ 4°C at normal laboratory conditions. Outer rotor ring: 25 positions for (STAT) samples, controls and calibrators 15 positions for reagent bottles All positions fit 13×75 mm primary and secondary tubes and pediatric cups All positions can be used for calibrators, controls, normal, pediatric and STAT samples. |
| Pipetting System | 100 μl reagent syringe: – R1 volume 110-400 μl – R2 volume 0-180 μl -R3 volume 0-180 μl – Programmable in 1 μl steps 100 μl sample syringe: – Sample volume 1-30 μl – Programmable in 0.1 μl steps – Programmable dilution ratios 1:5 up to 1:100 in one step increments with 3 possible diluents Pre-heated probe with level detection, collision protection and integrated mixer. |
| Cuvette Rotor | Disposable cuvette rotor with 48 cuvettes Minimum measurement volume 220 μl Measurement temperature 37°C, controlled by Peltier elements. |
| Light Source | Quartz-iodine lamp 12V-20W. Wavelength Range Optical unit with 8 position filter wheel Automatic wavelength selection 340, 405, 505, 546, 578, 620, 660 nm standard installed One free position Other wavelenghts available on request. |
| Photometric Range | -0.1 to 3.0 Absorbance Resolution 0.001 Abs. |
| Analytical Modes (Single, Dual and Triple reagent system) | Kinetic measurement with linearity check Mono and bichromatic end point measurement with or without bichromatic reagent blank and/or sample blank correction Two point measurement; with or without slope blank Graphic plot of all measuring points Automatic rerun with sample reduction Non-linear calibration curves Prozone check for immunology tests Cut-off declaration Calculated tests. |
| Quality Control | Up to 15 different controls can be defined, 3 per test Westgard rules Levey-Jennings plots Quality control statistics. |
| Standards and Regulations | CE -IVD CB. |
| Dimensions | 89 x 58 x 60 cm (W x H x D) No peripherals |
| Weight | 67 kg. |
| Interface | State of the art Host-Query interface available Host: RS 232 or Ethernet (TCP/IP) through LIS-2A protocol. |
| Environmental Conditions | Temperature: 15 – 32 °C Humidity: 15 – 85% RH Altitude: up to 2,000 m Plumbing: No dedicated water or drain required Electrical: – Voltage: 100 – 240 Vac – Frequency: 50 – 60 Hz – Power (max): 350 VA . |
| Barcode Reader | Hand held CCD bar code reader used for test requisition, reagent identification and automated programing of assays, controls, and calibrators. |
| Printer | Printer supported by MS Windowsâ„¢ |
| ProActive Maintenance Kit | Complete parts kit for annual preventive maintenance. |