Immuno Analyzer HIPRO A1
Jual Immuno Analyzer HIPRO A1, Tes Serologi – IgG & IgM SARS COV-2, A1 IMMUNOASSAY OTOMATIS.
Tersedia dengan harga terbaik hanya di Pusatgrosiralkes.com. Lihat lebih lengkap Spesifikasinya dibawah ini :
Jual Tes Serologi HIPRO A1, Immunoassay Analyzer – IgG & IgM SARS COV-2, A1 OTOMATIS.
PENGOPERASIAN SEDERHANA, Mudah dan Akurat.
3 INOVASI Teknologi Utama
Baterai Bawaan
Isi daya 3 Jam, Jalankan 30 Jam non-stop
Sistem Kalibrasi 3-level
Pastikan hasil yang andal dan akurat
Multi-metodologi
Berbagi platform reagen
Hasil Perbandingan Immuno Analyzer Hipro A1 IgG & IgM Sars Cov-2
Perbandingan sampel reaktif Sars Cov-2
Hipro A1 (Metode Nefelometri) dengan (Metode Eclia)

Nilai Normal :
ECLIA :
- > 1,0 COI (Hasil Reaktif)
- <1,0 COI (Hasil Non-Reaktif) NEPHELOMETRI: > 48 g / mL (Hasil Reaktif)
- <48 g / mL (Hasil Non-Reaktif)
Performa :
- Sensitivitas 90%
- Kekhususan 95%
Jual Tes Serologi HIPRO A1 dengan Fitur Utama :
- Sepenuhnya Otomatis
Kontrol suhu internal, pelepasan otomatis, kalibrasi Internet real-time. - Multi-Metodologi
Nefelometri, Biokimia, Turbidimetri, Imunofluoresensi - Ketepatan
Sistem Kalibrasi tiga tingkat, Kalibrasi Fisik, Kalibrasi online waktu nyata, Kalibrasi Sistem - Desain Portabel Untuk Kondisi Lingkungan
Saluran tunggal untuk daftar tes lengkap
Hasil <5 menit
5KG saja, Kecil dan portabel
Baterai built-in, 36 jam terus menerus bisa diterapkan tanpa catu daya AC.
Parameter Dasar
W × D × H : 410*355*280mm
Berat : 5kg
Catu daya : AC110 ~ 265V
Waktu uji sampel : <5 menit
Info Pasien. Masukan : Kode batang, RFID
Kontrol Kualitas : Perbarui kurva kalibrasi terbaru melalui Internet
Alat analisa immunoassay / immuno analyzer digunakan untuk mengidentifikasi dan mendeteksi konsentrasi zat tertentu dalam sampel, biasanya menggunakan antibodi sebagai reagen.
Sumber : https://www.beckmancoulter.com/products/immunoassay
DAPATKAN PENAWARAN TERBAIK DARI KAMI :
- JAMINAN KETERSEDIAAN STOK BARANG
- JAMINAN KETERSEDIAAN REAGENSIA KIMIA KLINIK
- JAMINAN SERVICE DAN MAINTENANCE
- JAMINAN HARGA YANG BERSAING
Pusatgrosiralkes.com Jual Tes Serologi HIPRO A1 dengan Harga Termurah dan Pelayanan Terbaik, lihat juga produk sejenis lainnya.
[block id=”footer-product”]
Related products
Mindray BC-5800
In stock
| Parameter | 25 parameter: WBC, Lym%, Mon%, Neu%, Bas%, Eos%, Lym #, Mon #, Neu #, Eos #, Bas #, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR, P-LCC. 4 Parameter penelitian termasuk LIC%, LIC #, ALY%, ALY # 2 Histogram untuk RBC dan PLT 2 Scatter gram: 4-diffter gram, Basophil scatter gram |
|---|---|
| Prinsip | Metode impedansi untuk menghitung RBC dan PLT Reagen bebas sianida untuk tes hemoglobin Flow Cytometry (FCM) + Laser light scatter + Metode pewarna kimia untuk analisis diferensial WBC dan penghitungan WBC |
| Kinerja | Rentang Linearitas Parameter Presisi Carryover WBC 0-250 × 10⁹ / L ≤2.5% (4-15 × 10⁹ / L) ≤0.5 % RBC 0-8,2 × 10¹² / L ≤1,5% (3,5-6,0 × 10¹² / L) ≤0,5 % HGB 0-260g / L ≤1,5% (110-180g / L) ≤1.0 % HCT 0-67% ≤1.5% (30% -50%) ≤0.5 % PLT 0-2000 × 10⁹ / L ≤4.0% (100-500 × 10⁹ / L) ≤1.0 % |
| Sample Volume | Prediluted 40 µL Mode manual (Open vial) 120 µL Auto loader / mode Manual (Closed tube) 180 µL |
| Throughput | Hingga 90 sampel per jam |
| Display | 10.4 inch TFT Touch Screen Resolusi: 800 × 600 |
| Banyak bahasa | China, Ceko, Inggris, Prancis, Jerman, Yunani, Italia, Polandia, Portugis, Rumania, Rusia, Spanyol, Turki |
| Kapasitas Penyimpanan Data | Hingga 40.000 hasil termasuk informasi numerik dan grafis |
| Komunikasi | Port LAN mendukung protokol HL7 dan 15ID |
| Antarmuka | USB, LAN, COM Mendukung Uni- atau LIS bi-directional |
| Printer | Printer Laser eksternal / printer Inkjet, berbagai format cetakan dan format yang ditentukan pengguna |
| Lingkungan operasi | Suhu: 15 ° C ~ 30 ° C Kelembaban: 30% ~ 85% |
| Kebutuhan daya | Unit utama: 100-240 V ~ 50/60 Hz Unit pneumatik: 110 / 115V ~ 60Hz 220/230 V ~ 50/60 Hz |
| Dimensi dan Berat | Unit utama Unit pneumatik Pengambil sampel (Opsional) Lebar (mm) 664 305 516 Kedalaman (mm) 613 475 237 Tinggi (mm) 585 425 90 Berat (kg) ≤76 ≤25 ≤8 |
Mindray BC-6800
In stock
| Parameter | 36 reportable parameters (whole blood): WBC, Lym%, Mon%, Neu%, Bas%, Eos%, IMG%, Lym#, Mon#, Neu#, Eos#, Bas#, IMG#; RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, RET%, RET#, IRF, LFR, MFR, HFR, NRBC#, NRBC%; PLT, MPV, PDW, PCT, P-LCR, P-LCC, IPF 18 research parameters (whole blood): HFC#, HFC%, WBC-R, WBC-D, WBC-B, WBC-N, RBC-O, PLT-O, PLT-I, PDW-SD, InR#, InR‰, Micro%, Micro#, Macro%, Macro#, MRV, RHE 7 reportable parameters (body fluid): WBC-BF, TC-BF#, MN#, MN%, PMN#, PMN%, RBC-BF 7 research parameters (body fluid): Eos-BF#, Eos-BF%, Neu-BF#, Neu-BF%, HF-BF#, HF-BF%, RBC-BF 2 histograms for RBC and PLT 3 scattergrams (3D) for DIFF, NRBC and RET 6 scattergrams (2D) for DIFF, BASO, NRBC, RET, RET-EXT, PLT-O |
|---|---|
| Prinsip | SF Cube cell analysis technology for WBC, 5-Part diff, NRBC, RET and PLT-O Focusing Flow-DC method for RBC and PLT Cyanide free hemoglobin measurement |
| Kinerja | Parameter Linearity Range Precision Carryover WBC 0-500×10⁹/L ≤2.5% (≥4×10⁹/L) ≤1.0% RBC 0-8×10¹²/L ≤1.5% (≥3.5×10¹²/L) ≤1.0% HGB 0-250g/L ≤1.0% (110-180g/L) ≤1.0% HCT 0-75% ≤1.5% (30%-50%) ≤1.0% PLT 0-5000×10⁹/L ≤4.0% (≥100×10⁹/L) ≤1.0% RET# 0-0.8×10¹²/L ≤15% (RBC≥3×10¹²/L; / 1%≤RET%≤4%) |
| Sample Volume | Predilute mode (capillary blood), Open vial 40μL Manual mode (whole blood), Open vial 150μL Autoloader mode (whole blood), Closed vial 200μL Manual mode (body fluid), Open vial 150μL |
| Throughput | Up to 125 samples per hour (CBC+DIFF) Up to 90 samples per hour (CBC+DIFF+RET) Up to 40 samples per hour (body fluid) |
| Loading capacity | Up to 100 sample tubes |
| Mode | CBC, CBC+DIFF, CBC+RET, CBC+NRBC, CBC+DIFF+RET, CBC+DIFF+NRBC, CBC+DIFF+RET+NRBC, RET |
| Data storage capacity | Up to 100,000 patient results including all numeric and graphical information |
| Printout | Various printout formats and user-defined formats available |
| Operating environment | Temperature: 15ºC~32ºC Humidity: 30%~85% |
OPTI CCA-TS Blood Gas
In stock
| Sample Volume | 125 µL (60µL for B60 cassette) |
|---|---|
| Calibration Time | <90 seconds |
| Measurement | <120 seconds |
| Typical Cycle Time | <210 seconds |
| Operating Temperature | 10–32°C (50–90°F) |
| Sample Type | Whole blood, serum or plasma |
| Measurement Principle | Optical fluorescence, reflectance |
| Sample Application | Syringe, capillary or ComfortSampler® |
| Data Storage | 200 patient records 70 QC samples per level 105 SRC samples per level 300 user IDs and passwords |
| Security | Password : Password-protected analyzer setup and delete functions QC Lockout : User-definable QC lockout functions |
| Dimensions/Weight | Height x Width x Depth : 124 x 362 x 230 mm (4.7 x 14.2 x 9.1 in) Weight : 5.5 kg (12 lb) with rechargeable battery pack |
| Miscellaneous | Voltage/Frequency : 120 or 240 AC, 50–60 Hz Power Consumption (max.) : 110 VA Interface : Serial, Ethernet* (*TS only) Approvals : CE, UL and IVDD |
Rayto RT-2600C Elisa Washer
In stock
| SizePlate mode | 96- or 48-well plate or strip |
|---|---|
| Dispense Precision | CV<2.0% |
| Residual Volume | <1 µL |
| Washing Volume | 50~3000µL for 8-way manifold 50~2000µLfor 12-way manifold |
| Washing Cycle | Maximum 99 cycles |
| Strip Washing | 1 to 12 channels adjustable |
| Soaking Time | 0~24 hour |
| Standard Wavelength: | Display 5” LCD |
| Bottle Capacity | 2 liters each |
| Memory | 50 washing protocols |
| Interface | RS-232 |
| Power Supply | AC 220V±10%, 50~60Hz, 110V on request |
| Net weight | 8Kg |
| Dimensions | L×W×H(mm) 390×340×180 |
Selectra Pro M
In stock
| Kecepatan | Sampai dengan 266 tes per jam Sampai dengan 180 tes per jam pada mode MONO |
|---|---|
| Sumber Cahaya | Lampu Quartz-iodine 12V-20W |
| Fotometrik | Absorbansi – 0.1 hingga 3.0; Resolusi 0,001 Abs. |
| Konsumsi Air | Maksimal ~500 ml per jam, dengan operasi terus menerus |
| Standard dan Regulasi | ce-ivD cb |
| Dimensi | 122 x 75 x 61 cm (P x T x L) |
| Berat | 95kg |
| Antarmuka | Host: RS232 atau Etherhet (TCP/IP) melalui protokol LIS-2A. |
Selectra Pro XS
In stock
| Throughput | Up to 75 tests per hour. |
|---|---|
| Reagent System | Inner rotor ring: 15 reagent positions for 10 ml, 25 ml and 50 ml reagent bottles Optionally cooled to 10°C +/ 4°C at normal laboratory conditions. Outer rotor ring: 25 positions for (STAT) samples, controls and calibrators 15 positions for reagent bottles All positions fit 13×75 mm primary and secondary tubes and pediatric cups All positions can be used for calibrators, controls, normal, pediatric and STAT samples. |
| Pipetting System | 100 μl reagent syringe: – R1 volume 110-400 μl – R2 volume 0-180 μl -R3 volume 0-180 μl – Programmable in 1 μl steps 100 μl sample syringe: – Sample volume 1-30 μl – Programmable in 0.1 μl steps – Programmable dilution ratios 1:5 up to 1:100 in one step increments with 3 possible diluents Pre-heated probe with level detection, collision protection and integrated mixer. |
| Cuvette Rotor | Disposable cuvette rotor with 48 cuvettes Minimum measurement volume 220 μl Measurement temperature 37°C, controlled by Peltier elements. |
| Light Source | Quartz-iodine lamp 12V-20W. Wavelength Range Optical unit with 8 position filter wheel Automatic wavelength selection 340, 405, 505, 546, 578, 620, 660 nm standard installed One free position Other wavelenghts available on request. |
| Photometric Range | -0.1 to 3.0 Absorbance Resolution 0.001 Abs. |
| Analytical Modes (Single, Dual and Triple reagent system) | Kinetic measurement with linearity check Mono and bichromatic end point measurement with or without bichromatic reagent blank and/or sample blank correction Two point measurement; with or without slope blank Graphic plot of all measuring points Automatic rerun with sample reduction Non-linear calibration curves Prozone check for immunology tests Cut-off declaration Calculated tests. |
| Quality Control | Up to 15 different controls can be defined, 3 per test Westgard rules Levey-Jennings plots Quality control statistics. |
| Standards and Regulations | CE -IVD CB. |
| Dimensions | 89 x 58 x 60 cm (W x H x D) No peripherals |
| Weight | 67 kg. |
| Interface | State of the art Host-Query interface available Host: RS 232 or Ethernet (TCP/IP) through LIS-2A protocol. |
| Environmental Conditions | Temperature: 15 – 32 °C Humidity: 15 – 85% RH Altitude: up to 2,000 m Plumbing: No dedicated water or drain required Electrical: – Voltage: 100 – 240 Vac – Frequency: 50 – 60 Hz – Power (max): 350 VA . |
| Barcode Reader | Hand held CCD bar code reader used for test requisition, reagent identification and automated programing of assays, controls, and calibrators. |
| Printer | Printer supported by MS Windows™ |
| ProActive Maintenance Kit | Complete parts kit for annual preventive maintenance. |

Reviews