Immuno Analyzer HIPRO A1
Jual Immuno Analyzer HIPRO A1, Tes Serologi – IgG & IgM SARS COV-2, A1 IMMUNOASSAY OTOMATIS.
Tersedia dengan harga terbaik hanya di Pusatgrosiralkes.com. Lihat lebih lengkap Spesifikasinya dibawah ini :
Jual Tes Serologi HIPRO A1, Immunoassay Analyzer – IgG & IgM SARS COV-2, A1 OTOMATIS.
PENGOPERASIAN SEDERHANA, Mudah dan Akurat.
3 INOVASI Teknologi Utama
Baterai Bawaan
Isi daya 3 Jam, Jalankan 30 Jam non-stop
Sistem Kalibrasi 3-level
Pastikan hasil yang andal dan akurat
Multi-metodologi
Berbagi platform reagen
Hasil Perbandingan Immuno Analyzer Hipro A1 IgG & IgM Sars Cov-2
Perbandingan sampel reaktif Sars Cov-2
Hipro A1 (Metode Nefelometri) dengan (Metode Eclia)

Nilai Normal :
ECLIA :
- > 1,0 COI (Hasil Reaktif)
- <1,0 COI (Hasil Non-Reaktif) NEPHELOMETRI: > 48 g / mL (Hasil Reaktif)
- <48 g / mL (Hasil Non-Reaktif)
Performa :
- Sensitivitas 90%
- Kekhususan 95%
Jual Tes Serologi HIPRO A1 dengan Fitur Utama :
- Sepenuhnya Otomatis
Kontrol suhu internal, pelepasan otomatis, kalibrasi Internet real-time. - Multi-Metodologi
Nefelometri, Biokimia, Turbidimetri, Imunofluoresensi - Ketepatan
Sistem Kalibrasi tiga tingkat, Kalibrasi Fisik, Kalibrasi online waktu nyata, Kalibrasi Sistem - Desain Portabel Untuk Kondisi Lingkungan
Saluran tunggal untuk daftar tes lengkap
Hasil <5 menit
5KG saja, Kecil dan portabel
Baterai built-in, 36 jam terus menerus bisa diterapkan tanpa catu daya AC.
Parameter Dasar
W × D × H : 410*355*280mm
Berat : 5kg
Catu daya : AC110 ~ 265V
Waktu uji sampel : <5 menit
Info Pasien. Masukan : Kode batang, RFID
Kontrol Kualitas : Perbarui kurva kalibrasi terbaru melalui Internet
Alat analisa immunoassay / immuno analyzer digunakan untuk mengidentifikasi dan mendeteksi konsentrasi zat tertentu dalam sampel, biasanya menggunakan antibodi sebagai reagen.
Sumber : https://www.beckmancoulter.com/products/immunoassay
DAPATKAN PENAWARAN TERBAIK DARI KAMI :
- JAMINAN KETERSEDIAAN STOK BARANG
- JAMINAN KETERSEDIAAN REAGENSIA KIMIA KLINIK
- JAMINAN SERVICE DAN MAINTENANCE
- JAMINAN HARGA YANG BERSAING
Pusatgrosiralkes.com Jual Tes Serologi HIPRO A1 dengan Harga Termurah dan Pelayanan Terbaik, lihat juga produk sejenis lainnya.
[block id=”footer-product”]
Related products
BS 3000M SINNOWA
In stock
| Methods | End point, Two points, Multi standard, Kinetic, Bichromatic and Serum blank, ect. |
|---|---|
| Test Program | 200 items, which may be modified and deleted |
| Capacity of Flow Cell | 32ul |
| Temperature Control | 25 ℃, 30 ℃, 37±0.1, room temperature. |
| Optical System: | Interferential filters, 340 / 405 / 492 / 510 / 546 / 578 / 620nm and two more filters available. |
| Light Source | 6V 10W halogen lamp. |
| Photometric Range | 0-2.5A |
| Display | LCD screen |
| Printer: | Built-in thermal printer |
| Serial Output | RS-232 standard |
| Dimension | 39cm×37cm×18cm |
Chemray 120
In stock
| Throughput | Lebih dari 100 test / jam. |
|---|---|
| Konten Pengujian | Clinical Chemistry, Immunoturbidimetric. |
| Mode Analisa | End-point, Two-point, Kinetic. |
| Programming | Open system with user defined programs. |
| Otomatis | Akses Acak. |
| Posisi Sampel | 9 posisi untuk sampel. |
| Ukuran Sampel | 3 ~ 45 uL, 0,5 uL adjustable. |
| Posisi Reagent | 26 Posisi untuk Reagent. |
| Ukuran Reagent | R1 : 180 ~ 450 uL, 1 uL adjustable. R2 : 3 ~ 450 uL, 1 uL adjustable. |
| Posisi Reaksi | 90 cuvettes, 10 cuvettes/strip. |
| Cuvette | Optical Length 5mm. |
| Ukuran Reaksi | 180 ~ 500ul. |
| Temperatur Reaksi | 37C, Fluctuation 0.3C. |
| Print Out | Built in thermal printer, external printer optional. |
Rayto 7300
In stock
| Aperture Diameter | WBC 80um; RBC 50um |
|---|---|
| Throughput | 60 samples per hour |
| Sample Volume | Prediluted: 20uL, Whole Blood: 9.8μuL |
| Display | 8.4′ Color LCD, Resolution: 640X480 |
| Alarms | Error messages |
| Carryover | WBC/RBC/HGB<0.5%, PLT<1.0% |
| Input/Output | RS-232, USB, LAN, keyboard and mouse interface |
| Printout | Thermal printer, 55mm width paper, various printout formats, external printer optional |
| Operating Environment | Temperature: 15~35; Humidity: 10%~90% |
| Power Requirement | AC 110-220V, 50/60Hz |
Rayto RT-2600C Elisa Washer
In stock
| SizePlate mode | 96- or 48-well plate or strip |
|---|---|
| Dispense Precision | CV<2.0% |
| Residual Volume | <1 µL |
| Washing Volume | 50~3000µL for 8-way manifold 50~2000µLfor 12-way manifold |
| Washing Cycle | Maximum 99 cycles |
| Strip Washing | 1 to 12 channels adjustable |
| Soaking Time | 0~24 hour |
| Standard Wavelength: | Display 5” LCD |
| Bottle Capacity | 2 liters each |
| Memory | 50 washing protocols |
| Interface | RS-232 |
| Power Supply | AC 220V±10%, 50~60Hz, 110V on request |
| Net weight | 8Kg |
| Dimensions | L×W×H(mm) 390×340×180 |
Selectra Pro XL
In stock
| Throughput | Up to 450 photometric and electrolyte tests/hour. |
|---|---|
| Reagent System | 64 refrigerated reagent positions for 10 mL, 25 mL and 50 mL reagent bottles Cooled to 10°C +/- 4°C at normal laboratory conditions All reagent positions can be assigned as R1, R2 and R3. |
| Sample System | 80 barcode readable positions All positions fit 13×75 or 16x 100mm primary and secondary tubes and pediatric cups All positions can be used for calibrators, controls, normal, pediatric and STAT samples |
| Pipetting System | 1000 µL reagent syringe: R1 volume 110-400 µL R2 volume 0-180 µL R3 volume 0-180 µL Programmable in 1 µL steps 100 µL sample syringe: Sample volume 1-30 µL Programmable in 0.1 µL steps Pre programmed ratio selectable from ratios 1:2 up to 1:100 with 3 diluents Pre-heated probe with level detection, collision protection and integrated mixer. |
| Cuvette Rotor | Cost effective, semi-disposable cuvette rotor with 48 cuvettes Up to 10.000 tests per rotor Typical reagent consumption 220 µL per test Measurement temperature 37°C, controlled by Peltier elements. |
| Light Source | Quartz-iodine lamp 12V-20W |
| Wavelength Range | Optical unit with 8 position filter wheel 340, 405, 505, 546, 578, 620, 660, 700 nm standard wavelengths Other wavelengths available on request. |
| Photometric Range | -0.1 to 3.0 Absorbance Resolution 0.001 Abs. |
| Analytical Modes (Single, Dual and Triple reagent system) | Kinetic measurement with linearity check Mono- and bichromatic end point measurement with or without bichromatic reagent blank and/or sample blank correction Two point measurement; with or without slope blank Graphic plot of all measuring points Predilution and automatic reflex dilution as needed Range of calibration models Non-linear calibration curves Prozone check for immunology tests Cut-off declaration Calculated tests. |
| Quality Control | Up to 15 controls can be defined, 3 per test Westgard or Basic QC rules Levey-Jennings plots Quality control statistics. |
| Standards and Regulations | CE -IVD CB UL. |
| Dimensions | 117 x 115 x 80 cm (W x H x D) 46.1 x 45.3 x 31.5 in(W x H x D) |
| Weight | 190 kg (419 lbs). |
| Interface | Host-Query interface available Host: RS 232 or Ethernet (TCP/IP) through LIS-2A protocol. |
| Environmental Conditions | Temperature: 15 – 32 °C (59 – 90 °F) Humidity: 15 – 88% RH Altitude: up to 2000 m Plumbing: No dedicated water or drain required Electrical: Voltage: 100 – 240 Vac Frequency: 50 – 60 Hz Power (max): 380 VA . |
| Integrated PC | Touch screen navigation Operating system: Windows™ XP |
| Barcode Reader | Hand held CCD barcode reader used for reagent identification |
| Eco Kit | Enables separate collection of concentrated measurement mixture and dilute (wash) waste |
| Dry ISE Module | Patented Solid State Electrode Technology Indirect measurement Dilution 1:14 Measures Sodium, Potassium, Chloride and CO2. |
| Positive Sample Identification | Positive Sample Identification (PSID) reads all popular barcodes. |
| Printer | Printer supported by MS Windows™. |
| ProActive Maintenance Kit | Complete parts kit for annual preventive maintenance. |
WP-330
In stock
| Parameter | WBC, RBC, HGB, MCV, MCH, MCHC, HCT, PLT, NEUT#, MXD#. LYM#, NEUT%, MXD%, LYM%, RDW-CV, RDW-SD, PDW, MPV, PCT, P-LCR, PLCC |
|---|---|
| Histogram | WBC, RBC, PLT |
| Principles | WBC, RBC, PLT: electrical resistance for counting Sa |
| Sample Volume | Pre Dil : 20 ul Whole Blood : 9,8 ul |
| Throughput | 30 samples/ hour |
| Display | 8 inch color lcd with mouse operation |
| Alarms | Error Message |
| Input/Output | RS232, USB Lan Keyboard Mouse |
| Print Out | Thermal Recorder, 55mm width paper, Various printout format, external printer optional |
| Operating Environment | Temperature 15⁰C-35⁰C, Relative humidity ≤80% |
| Reagent | Detergent, Diluent, BCC-3600 Lyse |
| Power Requirement | a.c 100-240 VAC 50/60 HZ |
| Dimension (mm) | 468 (L) x 325 (W) x 395 (H) |
| Weight | 16.5 Kg |

Reviews
Clear filtersThere are no reviews yet.