Showing 1–12 of 13 results

Alat Kimia Klinik adalah instrumen yang digunakan dalam laboratorium medis untuk menganalisis sampel biologis seperti darah, urin, dan cairan tubuh lainnya.

Tujuan utama dari alat kimia klinik ini adalah membantu dalam diagnosis, pemantauan, dan penelitian berbagai kondisi kesehatan, termasuk penyakit metabolik, infeksi, serta gangguan organ tubuh.

Alat Kimia Klinik

Chempro 3.0

In stock

SKU: PGA-CHEMPRO3.0
Detection MethodPhotometric detection
Detection time<3mins
CV<10%
Sample TypeSerum, whole blood, plasma
Sample volume45uL
Power supplyAdapter input AC100~240V,50/60Hz, 30VA: Output 5V,2A
Built-in Lithium batteryDC 3.7 +- 0.3V
Measurement157.5*145.7*64.6mm
Weight622g
Data storage3000 results
Display4.3′ touch screen
Storage environmentTemp 20C ~ 60C; Rh: 10% ~ 90%
Operation environmentTemp 15C ~ 35C; Rh:<85%

Chemray 120

In stock

SKU: PGA-CHEMRAY120
ThroughputLebih dari 100 test / jam.
Konten PengujianClinical Chemistry, Immunoturbidimetric.
Mode AnalisaEnd-point, Two-point, Kinetic.
ProgrammingOpen system with user defined programs.
OtomatisAkses Acak.
Posisi Sampel9 posisi untuk sampel.
Ukuran Sampel3 ~ 45 uL, 0,5 uL adjustable.
Posisi Reagent26 Posisi untuk Reagent.
Ukuran ReagentR1 : 180 ~ 450 uL, 1 uL adjustable. R2 : 3 ~ 450 uL, 1 uL adjustable.
Posisi Reaksi90 cuvettes, 10 cuvettes/strip.
CuvetteOptical Length 5mm.
Ukuran Reaksi180 ~ 500ul.
Temperatur Reaksi37C, Fluctuation 0.3C.
Print OutBuilt in thermal printer, external printer optional.

Chemray 240

In stock

SKU: PGA-CHEMRAY240
ThroughputLebih dari 160 test / jam.
Konten PengujianClinical Chemistry, Immunoturbidimetric.
Mode AnalisaEnd-point, Two-point, Kinetic.
ProgrammingOpen system with user defined programs.
OtomatisAkses Acak.
Posisi Sampel40 posisi untuk sampel.
Ukuran Sampel3 ~ 100 uL, 0,5 uL adjustable.
Posisi Reagent40 Posisi untuk Reagent. Refrigerated Temperatre : 16C
Ukuran ReagentR1 : 180 ~ 450 uL, 1 uL adjustable. R2 : 30 ~ 450 uL, 1 uL adjustable.
Posisi Reaksi81 cuvettes, 9 cuvettes/strip.
Cuvette8 Step Washer System.
Ukuran Reaksi180 ~ 500ul.
Temperatur Reaksi37C, Fluctuation 0.2C.

Glory 917

In stock

SKU: PGA-GLORY917-2024
Machine typeRandom access, open reagent & locked reagent (optional)
Test SpeedConstant 150 tests/hour (Mono reagent or double reagent)
Test PrincipleColorimetric method, turbidimetry
Test Method1 point end, 2 point end, Fixed-Time, Kinetics
Calibration TypeLinear & nonlinear
Sample Tray40 sample positions
Sample TubeMicro cup & test tube & blood collection tube can be used. ( Φ 12 -13 )mm * ( 25 – 100 ) mm
Sample Volume2-30μL, step by 0.1μL
Sample ProbeLiquid surface detection, timely tracking for liquid volume. Collision avoidance
Sample BarcodeSample barcode reader (optional)
Reagent Tray80 reagent positions (40 for R1 & 40 for R2), Non-stop cooling system with peltier pad inside, 24 hours 2°C-14°C, open system, could accept any reagent.
Reagent Volume20-300μl, step by 1μl
Reagent NeedleLiquid surface detection, timely tracking for liquid volume. Collision avoidance.
Regent BarcodeRegent barcode reader (optional)
Reaction tray44 reaction cuvettes, new amorphous optical plastics reaction cups, perfect transmittance.
Reaction Volume150μl-330μl
Reaction Time10 minutes
TemperaturePeltier pad incubation system, reaction temperature (37℃ ± 0.1℃)
MixerPaddle-type mixing, effective reducing of carry-over
Light SourceHalogen lamp
Wavelength340nm; 405nm; 450nm; 505nm; 546nm; 578nm; 630nm; 700nm(4 more options)
Absorbance range0-4.0 Abs
Resolution0.0001 Abs
Operation SystemWindows XP, Windows 7, Windows 8, Windows 10
Data ProcessingAutomatic calibration, test combination, effective time management of reagents, serum index, whole process detection, linear expansion of enzyme, blank deduction,dirty cuvette memory , cross infection prevention, patient information memory and association input, automatic report audit, data fuzzy query, report statistics and printing, reference range grading, alarm information classification, user operation privilege classification management.
Report Printing6 formats optional, surpport custom pattern
InterfaceTCP/IP network interface
Power SupplyAC 110/220V ± 10%, 50/60 Hz, 650W
Water Consumption6L/hour(maximum)
Dimension750mm * 560mm * 535mm(L*W*H)
Weight52 kg

PUSHKANG MS100

In stock

SKU: PGA-PUSHKANGMS100
Sample typeAnticoagulant whole blood, plasma, serum, capillary blood
Test principlePhotoelectric colorimetry
ConnectionOn-line of LIS system
Sample Volume140μL
Test time≦15min
Code identificationAutomatic identification of QR code for reagent disc
Reagent typeLyophilized reagent
Light sourceLED lamp
PrinterBuilt-in thermal printer and external printer (wireless printer driver)
Operating systemAndroid 5.1 (5-inch)
Memory capacity1GB, with expandable 32GB TF card
Supply voltageAC 100V-240V, 50-60HZ
Size270mm*180mm*155mm
Weight3 KG, with built-in adapter

Selectra Pro M

In stock

SKU: PGA-SELECTRAPRO-M
KecepatanSampai dengan 266 tes per jam Sampai dengan 180 tes per jam pada mode MONO
Sumber CahayaLampu Quartz-iodine 12V-20W
FotometrikAbsorbansi – 0.1 hingga 3.0; Resolusi 0,001 Abs.
Konsumsi AirMaksimal ~500 ml per jam, dengan operasi terus menerus
Standard dan Regulasice-ivD cb
Dimensi122 x 75 x 61 cm (P x T x L)
Berat95kg
AntarmukaHost: RS232 atau Etherhet (TCP/IP) melalui protokol LIS-2A.

Selectra Pro XL

In stock

SKU: PGA-SELECTRAPRO-XL
ThroughputUp to 450 photometric and electrolyte tests/hour.
Reagent System64 refrigerated reagent positions for 10 mL, 25 mL and 50 mL reagent bottles Cooled to 10°C +/- 4°C at normal laboratory conditions All reagent positions can be assigned as R1, R2 and R3.
Sample System80 barcode readable positions All positions fit 13×75 or 16x 100mm primary and secondary tubes and pediatric cups All positions can be used for calibrators, controls, normal, pediatric and STAT samples
Pipetting System1000 µL reagent syringe: R1 volume 110-400 µL R2 volume 0-180 µL R3 volume 0-180 µL Programmable in 1 µL steps 100 µL sample syringe: Sample volume 1-30 µL Programmable in 0.1 µL steps Pre programmed ratio selectable from ratios 1:2 up to 1:100 with 3 diluents Pre-heated probe with level detection, collision protection and integrated mixer.
Cuvette RotorCost effective, semi-disposable cuvette rotor with 48 cuvettes Up to 10.000 tests per rotor Typical reagent consumption 220 µL per test Measurement temperature 37°C, controlled by Peltier elements.
Light SourceQuartz-iodine lamp 12V-20W
Wavelength RangeOptical unit with 8 position filter wheel 340, 405, 505, 546, 578, 620, 660, 700 nm standard wavelengths Other wavelengths available on request.
Photometric Range-0.1 to 3.0 Absorbance Resolution 0.001 Abs.
Analytical Modes (Single, Dual and Triple reagent system)Kinetic measurement with linearity check Mono- and bichromatic end point measurement with or without bichromatic reagent blank and/or sample blank correction Two point measurement; with or without slope blank Graphic plot of all measuring points Predilution and automatic reflex dilution as needed Range of calibration models Non-linear calibration curves Prozone check for immunology tests Cut-off declaration Calculated tests.
Quality ControlUp to 15 controls can be defined, 3 per test Westgard or Basic QC rules Levey-Jennings plots Quality control statistics.
Standards and RegulationsCE -IVD CB UL.
Dimensions117 x 115 x 80 cm (W x H x D) 46.1 x 45.3 x 31.5 in(W x H x D)
Weight190 kg (419 lbs).
InterfaceHost-Query interface available Host: RS 232 or Ethernet (TCP/IP) through LIS-2A protocol.
Environmental ConditionsTemperature: 15 – 32 °C (59 – 90 °F) Humidity: 15 – 88% RH Altitude: up to 2000 m Plumbing: No dedicated water or drain required Electrical: Voltage: 100 – 240 Vac Frequency: 50 – 60 Hz Power (max): 380 VA .
Integrated PCTouch screen navigation Operating system: Windowsâ„¢ XP
Barcode ReaderHand held CCD barcode reader used for reagent identification
Eco KitEnables separate collection of concentrated measurement mixture and dilute (wash) waste
Dry ISE ModulePatented Solid State Electrode Technology Indirect measurement Dilution 1:14 Measures Sodium, Potassium, Chloride and CO2.
Positive Sample IdentificationPositive Sample Identification (PSID) reads all popular barcodes.
PrinterPrinter supported by MS Windowsâ„¢.
ProActive Maintenance KitComplete parts kit for annual preventive maintenance.

Selectra Pro XS

In stock

SKU: PGA-SELECTRAPRO-XS
ThroughputUp to 75 tests per hour.
Reagent SystemInner rotor ring: 15 reagent positions for 10 ml, 25 ml and 50 ml reagent bottles Optionally cooled to 10°C +/ 4°C at normal laboratory conditions. Outer rotor ring: 25 positions for (STAT) samples, controls and calibrators 15 positions for reagent bottles All positions fit 13×75 mm primary and secondary tubes and pediatric cups All positions can be used for calibrators, controls, normal, pediatric and STAT samples.
Pipetting System100 μl reagent syringe: – R1 volume 110-400 μl – R2 volume 0-180 μl -R3 volume 0-180 μl – Programmable in 1 μl steps 100 μl sample syringe: – Sample volume 1-30 μl – Programmable in 0.1 μl steps – Programmable dilution ratios 1:5 up to 1:100 in one step increments with 3 possible diluents Pre-heated probe with level detection, collision protection and integrated mixer.
Cuvette RotorDisposable cuvette rotor with 48 cuvettes Minimum measurement volume 220 μl Measurement temperature 37°C, controlled by Peltier elements.
Light SourceQuartz-iodine lamp 12V-20W. Wavelength Range Optical unit with 8 position filter wheel Automatic wavelength selection 340, 405, 505, 546, 578, 620, 660 nm standard installed One free position Other wavelenghts available on request.
Photometric Range-0.1 to 3.0 Absorbance Resolution 0.001 Abs.
Analytical Modes (Single, Dual and Triple reagent system)Kinetic measurement with linearity check Mono and bichromatic end point measurement with or without bichromatic reagent blank and/or sample blank correction Two point measurement; with or without slope blank Graphic plot of all measuring points Automatic rerun with sample reduction Non-linear calibration curves Prozone check for immunology tests Cut-off declaration Calculated tests.
Quality ControlUp to 15 different controls can be defined, 3 per test Westgard rules Levey-Jennings plots Quality control statistics.
Standards and RegulationsCE -IVD CB.
Dimensions89 x 58 x 60 cm (W x H x D) No peripherals
Weight67 kg.
InterfaceState of the art Host-Query interface available Host: RS 232 or Ethernet (TCP/IP) through LIS-2A protocol.
Environmental ConditionsTemperature: 15 – 32 °C Humidity: 15 – 85% RH Altitude: up to 2,000 m Plumbing: No dedicated water or drain required Electrical: – Voltage: 100 – 240 Vac – Frequency: 50 – 60 Hz – Power (max): 350 VA .
Barcode ReaderHand held CCD bar code reader used for test requisition, reagent identification and automated programing of assays, controls, and calibrators.
PrinterPrinter supported by MS Windowsâ„¢
ProActive Maintenance KitComplete parts kit for annual preventive maintenance.