Showing 1–12 of 15 results

Mindray

Mindray BA-88A

In stock

SKU: PGA-MINDRAYBA
PrinciplesALT, AST, ALP, ACP, GGT, α-HBDH, LDH, CK, AMY.TG.TC, HDL-C, UA, UREA, Cr, Glu, TP, Alb, T-bil, D-Bil, TBA, NH4+ , HCO3-, Ca, Mg, Cl , Na, K, apoAI , apoB, Lp ( a ), C3, C4 , lgG, lgA, lgM, HbA1c, Alcohol, Amphetamines, Barbiturates, Benzodiazepine etc .
Analysis MethodEndpoint , with or without reagent blank Endpoint , with sample blank and reagent blank Kinetics , with or without reagent blank Two-point Kinetics/Fixed-time , with or without reagent blank Absorbance Turbidimetry Linear and non-linear calibration
Light SourceTungsten-halogen Iamp 6V/10W
Wavelength RangeAutomatic by 8-position lter wheel 8 standard lters : 340nm , 405nm , 450nm , 510nm , 546nm , 578nm , 630nm and 670nm . Bandwidth < 8nm Stray light : < 0 . 1 % @ 340nm
Photometric Range0~3.5 ABS Stability : < 0 . 005A / 20min @ 340nm
FlowcellStainless steel with quartz window Measuring volume : 32 µL Optical path : 10mm Aspiration volume programmable : 200~9000 µL
InputTouch screen with touch pen and popup keypad Mouse or Keyboard via USB
Temperature ControlBy means of Peltier elements Room temperature , 25°C , 30 °C and 37°C
StorageMore than 3000 sample results More than 1000 QC results
PrinterBuilt-in thermal printer Supp
InterfaceRS232 serial port supporting data transmission USB port (2. 0) for keyboard , mouse , printer
Operating EnvironmentTemperature : 15°C~30°C Humidity : 35% ~85%, no condensation
Power RequirementWide power supply : AC 100-240V, 50 / 60Hz
Dimension430mm x 360mm x 170mm ( L x W x H )
Weight6.8 Kg

Mindray BC 30

In stock

SKU: PGA-MIDNRAYBC30
PrinciplesImpedance method for WBC, RBC and PLT counting Cyanide free reagent for hemoglobin test
Parameters21 parameters: WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR,P-LCC 3 histograms for WBC, RBC and PLT
Sample VolumePrediluted mode ≤20μL Whole blood mode ≤9 μL
PerformanceParameter Linearity Range Precision (CV %) Carryover WBC(109/L) 0-300 ≤3.5% (4.0-6.9) ≤0.5% ≤2.0% (7.0-15.0) RBC(1012/L) 0-8.00 ≤1.5% (3.50-6.5) ≤0.5% HGB(g/L) 0-280 ≤1.5% (100-180) ≤0.5% MCV(fL) ≤0.5% (70.0-110.0) ≤0.5% PLT(109/L) 0-4000 ≤5.0% (100-149) ≤1.0% ≤4.0% (150-500)
Throughput60 samples per hour
Display10.4 inch TFT Touch Screen
Multi LanguageChinese, English, Spanish, Portuguese, Russian, French, Bahasa Indonesia
Data storage capacityUp to 400,000 results including numeric and graphical information
CommunicationLAN Port supports HL7 protocol Support bi-directional LIS
Interface4 USB ports (for external printer, software upgrade, barcode reader, external WIFI, keyboard and mouse), LAN port (1)
PrintoutThermal recorder, 50 mm wide paper, various printouts formats External printer optional
Power Requirement(100V-240V)±10% ≤180VA (50Hz/60Hz) ±1Hz
Dimension and WeightDimension: Depth (410 mm) x width (300 mm) x height (400 mm) Weight: ≤20Kg

Mindray BC 30s

In stock

SKU: PGA-MIDNRAYBC30s
PrinciplesImpedance method for WBC, RBC and PLT counting Cyanide free reagent for hemoglobin test
Parameters21 parameters: WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR,P-LCC 3 histograms for WBC, RBC and PLT
ReagentM-30D DILUENT M-30CFL LYSE PROBE CLEANSER
Sample VolumePrediluted mode 20μL Whole blood mode 9 μL
PerformanceParameter Linearity Range Precision (CV %) Carryover WBC(109/L) 0-200 ≤3.5% (4.0-6.9) ≤0.5% ≤2.0% (7.0 -15.0) RBC(1012/L) 0-8.00 ≤1.5% (3.5-6.5) ≤0.5% HGB(g/L) 0-280 ≤1.5% (100 -180) ≤0.5% MCV(fL) ≤1.0% (70 -110) PLT(109/L) 0-4000 ≤5.0% (100 -149) ≤1.0% ≤4.0% (150 -500)
Throughput70 samples per hour
Display10.4 inch TFT Touch Screen
Multi LanguageChinese, English, Spanish, Portuguese, Russian, French, Bahasa Indonesia
Data storage capacityUp to 500,000 results including numeric and graphical information
CommunicationLAN Port supports HL7 protocol Support bi-directional LIS
Interface4 USB port (for external printer, software upgrade, barcode reader, WIFI adapter,keyboard and mouse), LAN port (1)
PrintoutThermal recorder, 50 mm wide paper, various printouts formats External printer optional
Operating EnvironmentTemperature: 10°C~40°C Humidity: 10%~90% Air pressure: 70kPa~106kPa
Power Requirement100V-240V ≤300VA 50Hz/60Hz
Dimension and WeightDimension: Depth(410 mm) x width(300 mm) x height(400 mm) Weight: ≤20Kg

Mindray BC 700 & BC 720

In stock

SKU: PGA-MIDNRAYBC700
PrinciplesWBC (IMG/Neu/Mon/Lym/Eos/Bas), NRBC/RET*,PLT-H/PLT-O*/IPF: SF Cube ^ Cell Analysis Technology ^S: Scatter; F: Fluorescence; Cube: 3D analysis
RBC, PLTFocusing Flow-DC Impedance Method
HGBColorimetric method
ESRPhotometric method
Number of measuring parameters (whole blood):109
Number of measuring parameters (body fluid):18
Number of reportable parameters:7 WBC-BF TC-BF# MN# MN% PMN# PMN% RBC-BF
Number of research parameters:11
Sample volumeCD (whole blood): 23ul CD+ESR (whole blood): 160ul Predilute: 20ul
Data storage capacityUp to 150,000 results including numeric and graphical information *
ThroughputCD 80t/h CDR 45t/h CD+ESR 40t/h
Whole bloodCBC, CBC + DIFF, CBC + DIFF + RET*, CD + ESR, CDR + ESR*, CD/WBC-3X, CDR/PLT-5X*, and other modes
PrediluteCBC, CBC + DIFF, CDR*, and other modes
Body fluidCBC + DIFF
Dimensions500D x 325W x 450H mm
Weight≤35Kg
Voltage100V-240V~ (±10%)
Frequency50Hz/60Hz (±1Hz)
Power input300VA
External outputLAN x 1 , USB x 4 (Specifications: DC 5V; 500mA; USB 2.0 x 3; USB 3.0 x 1)
Ambient temperature10℃ ~ 35℃
Relative humidity30% ~ 85%
Atmospheric pressure:70.0kPa ~ 106.0kPa^ ^Note : Required altitude for normal operation: -400m ~ +3000m
PerformanceParameter Linearity Range Precision Carryover WBC 0-500×10^9 /L ≤2.5% (≥4.51×10^9 /L) ≤ 1.0% RBC 0-8.60×10^12/L ≤1.5% (≥3.5×10^12/L) ≤ 1.0% HGB 0-260g/L ≤1.0% (110-180g/L) ≤ 1.0% HCT 0-75% ≤1.5% (30%-50%) ≤ 1.0% PLT* 0-5000×10^9 /L ≤ 1.5(SD) (≤20×10^9/L)^ ≤ 1.0% ≤ 2.5% (≥100×10^9/L)^ RET* 0-0.8×10^12/L ≤15% (RBC ≥ 3.00×10^12/L ≤ 1.0% RET%: 1.00% ~ 4.00%) ESR ≤1.8(SD)(0~20mm/h) ≤ 1.0% ^ Note: Applicable only to CDR/PLT-O 5x and CR/PLT-O 5x models Items marked with an asterisk (*) apply only to BC-720

Mindray BC 760 & BC 780

In stock

SKU: PGA-MIDNRAYBC760
PrinciplesWBC (IMG/Neu/Mon/Lym/Eos/Bas), NRBC/RET*,PLT-H/PLT-O*/IPF: SF Cube ^ Cell Analysis Technology ^S: Scatter; F: Fluorescence; Cube: 3D analysis
RBC, PLTFocusing Flow-DC Impedance Method
HGBColorimetric method
ESRPhotometric method
Number of measuring parameters (whole blood):109
Number of measuring parameters (body fluid):18
Number of reportable parameters:7 WBC-BF TC-BF# MN# MN% PMN# PMN% RBC-BF Number of research parameters: 11
Sample volumeCD (whole blood): 25ul CD+ESR (whole blood): 160ul Predilute: 20ul
Data storage capacityUp to 150,000 results including numeric and graphical information *
ThroughputCD 80t/h CDR 45t/h CD+ESR 40t/h
Whole bloodCBC, CBC + DIFF, CBC + DIFF + RET*, CD + ESR, CDR + ESR*, CD/WBC-3X, CDR/PLT-5X*, and other modes
PrediluteCBC, CBC + DIFF, CDR*, and other modes
Body fluidCBC + DIFF
Dimensions840D x 655W x 600H mm
Weight≤70.6Kg
Voltage100V-240V~ (±10%)
Frequency50Hz/60Hz (±1Hz)
Power input600VA
External outputLANx1 , USB x 4 (Specifications: DC 5V; 500mA; USB2.0 x 3; USB3.0 x 1 )
Ambient temperature10℃ ~ 35℃a
Relative humidity30% ~ 85%
Atmospheric pressure:70.0kPa ~ 106.0kPa^ ^Note : Required altitude for normal operation: -400m ~ +3000m
PerformanceParameter Linearity Range Precision Carryover WBC 0-500×10^9 /L ≤2.5% (≥4.51×10^9 /L) ≤ 1.0% RBC 0-8.60×10^12/L ≤1.5% (≥3.5×10^12/L) ≤ 1.0% HGB 0-260g/L ≤1.0% (110-180g/L) ≤ 1.0% HCT 0-75% ≤1.5% (30%-50%) ≤ 1.0% PLT* 0-5000×10^9 /L ≤ 1.5(SD) (≤20×10^9/L)^ ≤ 1.0% ≤ 2.5% (≥100×10^9/L)^ RET* 0-0.8×10^12/L ≤15% (RBC ≥ 3.00×10^12/L ≤ 1.0% RET%: 1.00% ~ 4.00%) ESR ≤1.8(SD)(0~20mm/h) ≤ 1.0% ^ Note: Applicable only to CDR/PLT-O 5x and CR/PLT-O 5x models Items marked with an asterisk (*) apply only to BC-720

Mindray BC-10

In stock

SKU: PGA-MIDNRAYBC10
PrinciplesImpedance method for WBC, RBC and PLT counting Cyanide free reagent for hemoglobin test
Parameters20 parameters: WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR 3 histograms for WBC, RBC and PLT
Sample VolumePrediluted mode ≤20μL Whole blood mode ≤9 μL
PerformanceParameter Linearity Range Precision (CV %) Carryover WBC(109/L) 0-100 ≤3.5% (4.0-6.9) ≤0.5% ≤2.0% (7.0-15.0) RBC(1012/L) 0-8.00 ≤2.0% (3.50-6.5) ≤0.5% HGB(g/L) 0-280 ≤2.0% (100-180) ≤0.5% MCV(fL) ≤1.0% (70.0-110.0) ≤0.5% PLT(109/L) 0-1000 ≤5.0% (100-500) ≤1.0%
Throughput30 samples per hour
Display8.4 inch TFT Touch Screen
Multi-languageChinese, English, Spanish, Portuguese, Russian, French, Bahasa Indonesia
Data Storage CapacityUp to 50,000 results including numeric and graphical information
CommunicationLAN Port supports HL7 protocol Support bi-directional LIS
Interface4 USB ports (for external printer, software upgrade, barcode reader, external WIFI, keyboard and mouse), LAN port (1)
PrintoutThermal recorder, 50 mm wide paper, various printouts formats
Power Requirement(100V-240V)±10% ≤180VA (50Hz/60Hz) ±1Hz
DimensionDepth (410 mm) x width (300 mm) x height (400 mm)
Weight≤20Kg

Mindray BC-11

In stock

SKU: PGA-MIDNRAYBC11
PrinciplesImpedance method for WBC, RBC and PLT counting Cyanide free reagent for hemoglobin test
Parameters20 parameters: WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR 3 histograms for WBC, RBC and PLT 2 research parameters: NLR, PLR
Sample VolumePrediluted mode ≤20μL Whole blood mode ≤9 μL
PerformanceParameter Linearity Range Precision (CV %) Carryover WBC(109/L) 0-100 ≤3.5% (4.0-6.9) ≤0.5% ≤2.0% (7.0-15.0) RBC(1012/L) 0-8.00 ≤2.0% (3.50-6.5) ≤0.5% HGB(g/L) 0-280 ≤2.0% (100-180) ≤0.5% MCV(fL) ≤1.0% (70.0-110.0) ≤0.5% PLT(109/L) 0-1000 ≤5.0% (100-500) ≤1.0%
Throughput30 samples per hour
Display8.4 inch TFT Touch Screen
Multi-languageChinese, English, Spanish, Portuguese, Russian, French, Bahasa Indonesia
Data Storage CapacityUp to 50,000 results including numeric and graphical information
CommunicationLAN Port supports HL7 protocol Support bi-directional LIS
Interface4 USB ports (for external printer, software upgrade, barcode reader, external WIFI, keyboard and mouse), LAN port (1)
PrintoutThermal recorder, 50 mm wide paper, various printouts formats
Power Requirement(100V-240V)±10% ≤180VA (50Hz/60Hz) ±1Hz Temperature: 15°C~30°C Humidity: 10%~90% Air pressure: 70kPa~106kPa
DimensionDepth (410 mm) x width (300 mm) x height (400 mm)
Weight≤20Kg

Mindray BC-2800

In stock

SKU: PGA-MIDNRAYBC2800
ParameterWBC, Lymph #, Mid #, Gran #, Lymph%, Mid%, Gran%, RBC, HGB, HCT, MCV, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT dan Histogram untuk WBC, RBC, PLT
PrinsipMetode impedansi listrik untuk penghitungan dan metode bebas sianida untuk hemoglobin.
KinerjaParameter Linearity Range Precision (CV%) WBC (10⁹ / L) 0,0-99.9 3 (4.0-15.0) RBC (10¹² / L) 0,0-9,99 2 (3,0-6,5) HGB (g / L) 0-300 2 (100-180) MCV (fL) 1 (70-100) PLT (10⁹ / L) 0-999 5 (200-500)
Volume ContohPrediluted 20 μL Seluruh Darah 13 μL
Diameter Lubang80 μm
Throughput30 sampel per jam
Time to result, open tube inlet<50 sec
DisplayLayar LCD berwarna Resolusi: 640 x 480
MenopangWBC, RBC, HGB≤0,5%, PLT≤1%
Input outputRS232 x 2, 1 printer paralel (opsional), pemindai kode 1 bar (opsional) 1 antarmuka keyboard
PrinterPerekam thermal, kertas lebar 50mm, banyak format cetakan, printer opsional
Lingkungan operasiSuhu: 15 ° C ~ 30 ° C Kelembaban: 30% ~ 85%
Kebutuhan dayaAC100-240V, 50 / 60Hz
Dimensi322 (W) x 437 (H) x 386 (D)
Berat17,9 Kg

Mindray BC-3000 Plus

In stock

SKU: PGA-MIDNRAYBC3000P
ParameterWBC, Lymph #, Mid #, Gran #, Lymph #, Mid%, Gran%, Lymph%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT dan Histogram untuk WBC, RBC, PLT
PrinsipMetode impedansi listrik untuk penghitungan dan metode bebas sianida untuk hemoglobin.
KinerjaParamter Linearity Range Precision (CV%) WBC (109 / L) 0,3-99,9 2,5 (7,0-15,0) RBC (1012 / L) 0. 20 – 8.00 2 (3,50 -6. 00) HGB (g / L) 10-250 1. 5 (110 -180) MCV (fL) 0. 5 (80,0-11 0,0) PLT (109 / L) 10-999 5 (150-500)
Volume ContohPrediluted 20 μL Seluruh Darah 13 μL
Diameter LubangWBC 100 µm RBC / PLT 70 µm
Throughput60 sampel per jam
DisplayLayar LCD warna besar Resolusi: 800 x 600 Alarm – 41 pesan kesalahan
MenopangWBC, RBC, HGB ≤ 0,5%, PLT ≤ 1%
Input outputRS232 x 2, 1 printer paralel (opsional), pemindai kode 1 bar (opsional) 1 antarmuka keyboard
PrinterThermaI recorde, kertas lebar 50 mm, banyak format cetakan, printer opsional
Lingkungan operasiSuhu 15 ° C ~ 30 ° C Kelembaban 30% ~ 85%
Kebutuhan dayaAC 100-240V, 50 / 60Hz
Dimensi390 (W) x 460 (H) x 400 (D)
Berat21 Kg

Mindray BC-5150

In stock

SKU: PGA-MIDNRAYBC5150
Parameter25 parameters: WBC, Lym%, Mon%, Neu%, Bas%, Eos%, Lym#, Mon#, Neu#, Eos#, Bas#, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR, P-LCC. 4 research parameters including LIC%, LIC#, ALY%, ALY# 3 histograms for WBC, RBC and PLT 3 scattergrams for WBC differential
PrinsipImpedance method for RBC and PLT counting Cyanide free reagent for hemoglobin test Flow Cytometry (FCM) + Tri-angle laser scatter + Chemical dye method for WBC 5-part differential analysis and WBC counting
KinerjaParameter Linearity Range Precision Carryover WBC 0-500×109/L ≤2% (4-15×109/L) ≤0.5% RBC 0-8×10¹²/L ≤1.5% (3.5-6.0×10¹²/L) ≤0.5% HGB 0-250g/L ≤1.5% (110-180g/L) ≤0.6% PLT 0-5000×109/L ≤4.0% (100-500×109/L) ≤1.0%
ReagentDiluent, DIFF lyse, LH lyse, probe cleanser
Sample VolumePrediluted mode 20 μL Whole blood mode 15 μL Capillary whole blood mode 15 μL
Throughput60 sampel per jam
Display10.4 inch TFT Touch Screen
Multi-languageChinese, English
Data Storage CapacityUp to 40,000 results including numeric and graphical information
CommunicationLAN port supports HL7 protocol
InterfaceUSB, LAN Support uni-directional LIS
PrintoutExternal Laser printer / Inkjet printer, various printout formats and user-defined formats
Operating EnvironmentTemperature: 10°C~30°C Humidity: 20%~85% Air pressure: 70 kPa~106 kP
Dimension and WeightDepth(400 mm) x width(320 mm) x height(410 mm) Weight :24kg Power requirement 100V-240V 50Hz/60Hz

Mindray BC-5300

In stock

SKU: PGA-MIDNRAYBC5300
Parameter27: WBC, Lym%, Mon%, Neu%, Eos%, Bas%, Lym #, Mon #, Neu #, Eos #, Bas #, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, LIC%, LIC #, ALY%, ALY # 3 histogram dan 1 scattergram
PrinsipFlow Cytometry (FCM), penghamburan Laser Semi-konduktor, pewarna kimia Metode, saluran Basophil independen Metode impedansi untuk perhitungan WBC, RBC, PLT Reagen bebas sianida untuk tes Hemoglobin
KinerjaCarryover Precision Linearity WBC ≤ 0,5% ≤ 2,0% (4-15 x 10⁹ / L) 0,00-99,99 x10⁹ / L RBC ≤ 0,5% ≤ 1,5% (3,5-6,0 x 10¹² / L) 0,00-8,00 x10¹² / L HGB ≤ 0,5% ≤ 1,5% (110-180g / L) 0-250g / L PLT ≤ 1.0% ≤ 4.0% (150-500 x 10⁹ / L) 0-1000 x10⁹ / L
Sample VolumeDarah Utuh: 20 μL Prediluted: 20 μL
Throughput60 sampel per jam
Mode TesCBC CBC + DIFF
Kapasitas Penyimpanan DataHingga 40.000 hasil termasuk informasi numerik dan grafis
KomunikasiPort LAN mendukung protokol HL7
Lingkungan OperasiSuhu: 15 ° C ~ 30 ° C Kelembaban: 30 ~ 85% Tekanan Udara: 70 ~ 106 kPa
Kebutuhan DayaA.C 100-240V ≤ 300VA 50 / 60Hz
Dimensi dan Berat410mm (L) x 470mm (W) x 530mm (H) Berat: ≤45 Kg

Mindray BC-5500

In stock

SKU: PGA-MIDNRAYBC5500
Parameter27: WBC, Lym%, Mon%, Neu%, Eos%, Bas%, Lym #, Mon #, Neu #, Eos #, Bas #, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, LIC%, LIC #, ALY%, ALY # 2 histogram dan 2 scattergram
PrinsipMetode, saluran Basophil independen Metode impedansi untuk perhitungan WBC, RBC, PLT Reagen bebas sianida untuk tes Hemoglobin
KinerjaParameter : Linearity Range WBC (10 /L) : 1.00-99.99 RBC (10 /L) : 0.30-8.20 HGB (g/L) : 1-260 PLT (10 /L) : 10-100
Sample VolumePrediluted : 40uL Manual Mode (Open Sampling) : 12uL Auto Loader / Manual Mode ( Closed tube) : 180uL
Throughput80 sampel per jam
Display10.4 inch TFT Touch Screen Resolution 800×600
MenuCount, Review, QC, Setup , Service, Calibration, Logout, Shutdown
Carry OverWBC, RBC, HGB, PLT<1.0%
InterfaceUSB, LAN Support bidirection and unidirection communication models
PrintoutExternal Laser Printer / Inkjet printer, various printout formats
Operating EnvironmentTemperature 15C ~ 30c Humidity 30%-85%
Kebutuhan DayaMain Unit : 100-240V ~50/60Hz Compressor : 110/115V ~50/60Hz, 220/230V ~50/60Hz
Dimension and WeightMain Unit : 664x613x585 (LxWxH)(mm) Compressor : 305x475x425 (LxWxH)(mm) Sample loader (optional) : 516x237x90 (LxWxH)(mm)