Showing all 8 results

Photometer

AMS NB-201

In stock

SKU: PGA-AMSNB-201
Sumber Cahaya

Quartz Halogen Lamp 12V/20W

Rentang Panjang Gelombang

• Automatic By 8 Position Filter Wheel
• 7 Standart Filiter ; 340nm, 405nm, 492nm, 510nm, 546nm, 578nm, 630nm
• 1 Position Free For Optional Filter
• Half Bandwidth <8 Nm
• Stray Light ; <0.3% At 340nm

Rentang Fotometrik

• 0,0000 Hingga 3,0000 ABS
• Resolusi; 0,0001 ABS
• Stabilitas; 0,002 A/Jam

Flowcell

• Stainless Steel With Quartz Window
• Measuring Volume 32 µl
• Optical Path 10mm
• Aspirition Volume Programmable ; 200-300 µl
• Carryover <1.0%

Metode Analisis

• End-Point, Dengan Atau Tanpa Reagen Kosong
• End-Point, Dengan Sampel Hambar, Dengan Atau Tanpa Reagen Kosong
• Kinetik, Dengan Atau Tanpa Pemeriksaan Linieritas
• Kinetik Dua Titik/Waktu Tetap, Dengan Atau Tanpa Reagen Kosong
• Absorbance
• Turbidimetry
• Kalibrasi Linier Dan Non-Linier

Pengaturan Parameter

• Metode
• Panjang Gelombang
• Suhu
• Reagen Kosong Y/N
• Sampel Kosong Y/N
• Jeda Waktu
• Waktu Pengukuran
• Waktu Reaksi
• Batas Serapan
• Volume Aspirasi
• Standar
• Pemeriksaan Linearitas
• Satuan Untuk Hasil

Penyimpanan

• 112 Profil Uji
• 3200 Hasil Sampel

Pengatur Suhu

By Means Of Pelitier Elements 25oC, 30oC, 37oC + 0.1oC

Input

Layar Sentuh

Tampilan

Layar LCD Besar

Print

Perekam Termal Bawaan

Interface

RS-232 Serial Port

Operating Environment

• Suhu : 10C – 30C
• Kelembaban : < 70%

Kebutuhan Daya

AC 220V/110V + 10%, 50Hz + 2%

Dimensi

(P) 420mm x (L) 380mm x (T) 170mm

Berat

8.5 kg

BIOC Intherma 168

In stock

SKU: PGA-INTHERMA168
Optic

340, 405, 505, 546, 578, 620, 670nm. One more optional filter.

Light Source

Hologen 6V / 10W.

Resolution

0.001Abs.

Photometric Range

0.000-3 . 000Abs.

Stability Of Absorbency

Change<0.005 Abs per hour.

Repeatability

CV<0,5 %.

Carry over

< 1%

Linearity

R>0.999.

Flow Cell

32 ul with peltier temperature control (25′C, 30′C, 37′C).

Memory

200 Tets programs and over 100.000 test result.

Display

7″ TFT LCD.

Printer

Builth-in thermal printer.

Data Communication

RS-232, SD card and USB.

CPU

High speed embedded processor.

Power Supply

AC 100-240V, 50/60Hz.

Weight

7 Kg.

Dimension (mm)

420(L) x 310(W) x 152(H).

BS 3000M SINNOWA

In stock

SKU: PGA-BS3000M
Methods

End point, Two points, Multi standard, Kinetic, Bichromatic and Serum blank, ect.

Test Program

200 items, which may be modified and deleted

Capacity of Flow Cell

32ul

Temperature Control

25 ℃, 30 ℃, 37±0.1, room temperature.

Optical System:

Interferential filters, 340 / 405 / 492 / 510 / 546 / 578 / 620nm and two more filters available.

Light Source

6V 10W halogen lamp.

Photometric Range

0-2.5A

Display

LCD screen

Printer:

Built-in thermal printer

Serial Output

RS-232 standard

Dimension

39cm×37cm×18cm

Glory 127

In stock

SKU: PGA-GLORY127
Reading Cuvette

Both flow through cell and direct reading cuvette

Photometric System

Light Source 6V/10W halogen lamp

Wavelength

340/405/492/510/546/578/620nm, 2 more filter on request

Wavelength Accuracy

2nm

Thermostatic Control

Temperatur 25C, 30C, 37C, Precision 2nm

Measuring System

Method : End Point, Fixed Time, Multistandart, Differential, Bichromatic and Immunoturbidimetric.

Measuring Range

0-3.000 O.D

Photometric Linearity

2% (0-3.000 O.D)

Photometeric Accuracy

1% (0-3.000 O.D)

Storage

Over 200 programs, 1000 test result

Incubator

20 incubating positions

Display

Black-illuminated LCD

Printer

Built in thermal printer

Interface

RS-232 Serial port for additional PC, USB port on request

Power Supply

AC110V / 60Hz or 220V / 50Hz

Dimensions

340mm, 380mm, 180mm

Weight

8.0 Kg

Microlab 300

In stock

SKU: PGA-MICROLAB300
Light Source

Quartz-iodine lamp 12V-20W.

Wavelength Range

Optical unit with 12 position filter wheel
340, 405, 505, 546, 578, 620 nm standard installed
6 positions for optional filters.

Photometric Range

0.1 to 2.3 Absorbance
Resolution 0.001 Abs.

Detector

Photo diode (320-1000 nm).

Blanking

Automatic zero setting.

Operator Interface

Membrane keyboard, for direct function and alpha-numeric entry
Optional external keyboard
High contrast graphical LCD display
Real time clock, 24 hours system.

Measurement Procedures

Kinetic measurement with linearity check
Kinetic, with linearity check and sample slope blank
Two point kinetic, with or without reagent blank
End point, with or without reagent blank
Bichromatic end point, with or without reagent blank
End point, with sample blank and with or without reagent blank.

Multiple Testing

Up to nine replicates
Means, SD and CV.

Measurement Time

Programmable, 2 to 998 seconds for kinetic and two point type of tests
For end point fixed at 2 seconds.

Delay Time

Programmable, 0 to 999 seconds.

Parameter Setting

Method name
Measurement mode
Wavelength 1 and 2
Aspiration volume
Measurement delay
Measurement time
Factor
Concentration standards
Reagent blank y/n
Sample blank y/n
Units for results
Levels for flagging
Curve fit y/n
Linearity check.

Calibration

Factor, one-point, two-point and multi-point
Automatic on 1 standard (linear mode)
Automatic on up to 10 standards (non-linear mode).

Quality Control

Two controls per test
QC survey of last 30 control measurements
Levey Jenning plot
High/low flags.

Flowcell

Metal, with quartz windows, measuring volume 30 µL.

Temperature Control

By means of Peltier elements
Fixed temperature at 37°C.

Aspirator System

Internal pump of bellows type, driven by stepper motor:
Back panel connection for waste
Aspiration volume programmable.

Printer

Internal matrix printer
Normal paper
External printer port available.

Signal Interface

Centronics type parallel port
RS 232 type serial port
PS 2 type port for external keyboard.

Standards and Regulations

CE -IVD
CB
UL.

Dimensions and Power Requirements

40 x 17 x 36,6 cm (W x H x D)
Weight: 8,5 kg.
100-240 VAC nominal, 50/60 Hz
Battery back-up to retain data

Mindray BA-88A

In stock

SKU: PGA-MINDRAYBA
Principles

ALT, AST, ALP, ACP, GGT, α-HBDH, LDH, CK, AMY.TG.TC, HDL-C, UA, UREA,
Cr, Glu, TP, Alb, T-bil, D-Bil, TBA, NH4+ , HCO3-, Ca, Mg, Cl , Na, K, apoAI ,
apoB, Lp ( a ), C3, C4 , lgG, lgA, lgM, HbA1c, Alcohol, Amphetamines,
Barbiturates, Benzodiazepine etc .

Analysis Method

Endpoint , with or without reagent blank
Endpoint , with sample blank and reagent blank
Kinetics , with or without reagent blank
Two-point Kinetics/Fixed-time , with or without
reagent blank
Absorbance
Turbidimetry
Linear and non-linear calibration

Light Source

Tungsten-halogen Iamp 6V/10W

Wavelength Range

Automatic by 8-position lter wheel
8 standard lters : 340nm , 405nm , 450nm , 510nm , 546nm , 578nm ,
630nm and 670nm . Bandwidth < 8nm
Stray light : < 0 . 1 % @ 340nm

Photometric Range

0~3.5 ABS
Stability : < 0 . 005A / 20min @ 340nm

Flowcell

Stainless steel with quartz window
Measuring volume : 32 µL
Optical path : 10mm
Aspiration volume programmable : 200~9000 µL

Input

Touch screen with touch pen and popup keypad
Mouse or Keyboard via USB

Temperature Control

By means of Peltier elements
Room temperature , 25°C , 30 °C and 37°C

Storage

More than 3000 sample results
More than 1000 QC results

Printer

Built-in thermal printer
Supp

Interface

RS232 serial port supporting data transmission
USB port (2. 0) for keyboard , mouse , printer

Operating Environment

Temperature : 15°C~30°C
Humidity : 35ï¼… ~85%, no condensation

Power Requirement

Wide power supply : AC 100-240V, 50 / 60Hz

Dimension

430mm x 360mm x 170mm ( L x W x H )

Weight

6.8 Kg

Rayto RT-1904C

In stock

SKU: PGA-RAYTO1904C
Photometric Range

0,500 – 3,000Abs

Resolution

0,001 Abs (displayed), 0,0001 Abs (calculated)

Light Source

Halogen lamp, 6V/10W

Wavelength Accuracy

± 1 nm

Band width

8 nm

Aspirate Volume

100 – 3000 ul

Cross Contamination Rate

< 0,1%

Memory

160 test protocols, minimum 1000 test result

Interface

RS-232, LAN Connector

Flow Cell

25 ul Metal-quartz flow cell

Cuvette Mode

12,5 mm x 12,5 mm cuvette optional

Temperature Control

25º C, 30º C, 37º C, ±0,1º c

Display

7" color LCD

Input

Mouse and Optional external keyboard

Weight

6.8 Kg

Output

Built-in printer or external printer (optional), SD Card

Net Weight

8 Kg

Dimensions

L x W x H (mm) : 460 x 330 x 140

Power Supply

AC 110V-220V ± 10%, 50-60 Hz

Wap Lab WP-9200

In stock

SKU: PGA-WP9200
Absorbance Range

0.500 – 3.000 Abs

Resolution

0.001 Abs (displayed), 0.0001 Abs (calculated)

Light Source

Halogen Lamp

Wavelength Accuracy

340, 405, 500, 546, 620nm, 3 more filters optional
± 1nm

Band width

< 8nm

Aspirate Volume

100 – 3000 ul

Cross Contamination Rate

< 1%

Interface

RA-232 serial cable

Flow Cell

Metal – quartz flow cell

Temperature Control

25˚C, 30˚C, 37˚C, ± 0.1˚C and ambient temperature

Display

LCD display

Output

Internal printer or external printer (optional)

Net Weight

7 KG

Dimensions

L x W x H (mm) : 360 x 318 x 160

Power Supply

AC 100V – 240 ± 10%, 50-60 Hz