Showing 25–36 of 188 results
Pusatgrosiralkes
BS 3000M SINNOWA
Rated 0 out of 5
In stock
SKU:
PGA-BS3000M
| Methods | End point, Two points, Multi standard, Kinetic, Bichromatic and Serum blank, ect. |
|---|---|
| Test Program | 200 items, which may be modified and deleted |
| Capacity of Flow Cell | 32ul |
| Temperature Control | 25 ℃, 30 ℃, 37±0.1, room temperature. |
| Optical System: | Interferential filters, 340 / 405 / 492 / 510 / 546 / 578 / 620nm and two more filters available. |
| Light Source | 6V 10W halogen lamp. |
| Photometric Range | 0-2.5A |
| Display | LCD screen |
| Printer: | Built-in thermal printer |
| Serial Output | RS-232 standard |
| Dimension | 39cm×37cm×18cm |
Centrifuge WP-0412 WAP LAB
Rated 0 out of 5
In stock
SKU:
PGA-CENWP0412WAP
| Maks. Kecepatan (Rpm) | 300-4500, kenaikan: 100 |
|---|---|
| Maks. RCF (×G) | 2490×g, kenaikan: 100×g |
| Akurasi Kecepatan (Rpm) | ±20 |
| Kapasitas Rotor | 10mL/7mL/5mL×12; 15mL×8 |
| Waktu Pengoperasian | 30 detik-99 menit-TAHAN (Operasi berkelanjutan) |
| Motor Penggerak | Motor DC tanpa sikat |
| Perangkat Keamanan | Interlock pintu, Detektor kecepatan berlebih; Diagnosis internal otomatis |
| Daya | Fase tunggal, 110V-240V, 50Hz/60Hz, 3A |
| Tingkat Kebisingan (Db) | ≤56 |
| Waktu Akselerasi / Pengereman (Detik) | 20s↑20s↓ |
| Dimensi (Mm) | (P)255 ×(L)245×(T)140 |
| Berat | 6 kg |
| Fitur Tambahan | Sakelar Kecepatan/RCF; Fungsi jangka pendek; fungsi peringatan suara |
Chempro 3.0
Rated 0 out of 5
In stock
SKU:
PGA-CHEMPRO3.0
| Detection Method | Photometric detection |
|---|---|
| Detection time | <3mins |
| CV | <10% |
| Sample Type | Serum, whole blood, plasma |
| Sample volume | 45uL |
| Power supply | Adapter input AC100~240V,50/60Hz, 30VA: Output 5V,2A |
| Built-in Lithium battery | DC 3.7 +- 0.3V |
| Measurement | 157.5*145.7*64.6mm |
| Weight | 622g |
| Data storage | 3000 results |
| Display | 4.3′ touch screen |
| Storage environment | Temp 20C ~ 60C; Rh: 10% ~ 90% |
| Operation environment | Temp 15C ~ 35C; Rh:<85% |
Chemray 120
Rated 0 out of 5
In stock
SKU:
PGA-CHEMRAY120
| Throughput | Lebih dari 100 test / jam. |
|---|---|
| Konten Pengujian | Clinical Chemistry, Immunoturbidimetric. |
| Mode Analisa | End-point, Two-point, Kinetic. |
| Programming | Open system with user defined programs. |
| Otomatis | Akses Acak. |
| Posisi Sampel | 9 posisi untuk sampel. |
| Ukuran Sampel | 3 ~ 45 uL, 0,5 uL adjustable. |
| Posisi Reagent | 26 Posisi untuk Reagent. |
| Ukuran Reagent | R1 : 180 ~ 450 uL, 1 uL adjustable. R2 : 3 ~ 450 uL, 1 uL adjustable. |
| Posisi Reaksi | 90 cuvettes, 10 cuvettes/strip. |
| Cuvette | Optical Length 5mm. |
| Ukuran Reaksi | 180 ~ 500ul. |
| Temperatur Reaksi | 37C, Fluctuation 0.3C. |
| Print Out | Built in thermal printer, external printer optional. |
Chemray 240
Rated 0 out of 5
In stock
SKU:
PGA-CHEMRAY240
| Throughput | Lebih dari 160 test / jam. |
|---|---|
| Konten Pengujian | Clinical Chemistry, Immunoturbidimetric. |
| Mode Analisa | End-point, Two-point, Kinetic. |
| Programming | Open system with user defined programs. |
| Otomatis | Akses Acak. |
| Posisi Sampel | 40 posisi untuk sampel. |
| Ukuran Sampel | 3 ~ 100 uL, 0,5 uL adjustable. |
| Posisi Reagent | 40 Posisi untuk Reagent. Refrigerated Temperatre : 16C |
| Ukuran Reagent | R1 : 180 ~ 450 uL, 1 uL adjustable. R2 : 30 ~ 450 uL, 1 uL adjustable. |
| Posisi Reaksi | 81 cuvettes, 9 cuvettes/strip. |
| Cuvette | 8 Step Washer System. |
| Ukuran Reaksi | 180 ~ 500ul. |
| Temperatur Reaksi | 37C, Fluctuation 0.2C. |