Showing 1–12 of 13 results
Auto Chemistry Analyzer
Chempro 3.0
Rated 0 out of 5
In stock
SKU:
PGA-CHEMPRO3.0
| Detection Method | Photometric detection |
|---|---|
| Detection time | <3mins |
| CV | <10% |
| Sample Type | Serum, whole blood, plasma |
| Sample volume | 45uL |
| Power supply | Adapter input AC100~240V,50/60Hz, 30VA: Output 5V,2A |
| Built-in Lithium battery | DC 3.7 +- 0.3V |
| Measurement | 157.5*145.7*64.6mm |
| Weight | 622g |
| Data storage | 3000 results |
| Display | 4.3′ touch screen |
| Storage environment | Temp 20C ~ 60C; Rh: 10% ~ 90% |
| Operation environment | Temp 15C ~ 35C; Rh:<85% |
Chemray 120
Rated 0 out of 5
In stock
SKU:
PGA-CHEMRAY120
| Throughput | Lebih dari 100 test / jam. |
|---|---|
| Konten Pengujian | Clinical Chemistry, Immunoturbidimetric. |
| Mode Analisa | End-point, Two-point, Kinetic. |
| Programming | Open system with user defined programs. |
| Otomatis | Akses Acak. |
| Posisi Sampel | 9 posisi untuk sampel. |
| Ukuran Sampel | 3 ~ 45 uL, 0,5 uL adjustable. |
| Posisi Reagent | 26 Posisi untuk Reagent. |
| Ukuran Reagent | R1 : 180 ~ 450 uL, 1 uL adjustable. R2 : 3 ~ 450 uL, 1 uL adjustable. |
| Posisi Reaksi | 90 cuvettes, 10 cuvettes/strip. |
| Cuvette | Optical Length 5mm. |
| Ukuran Reaksi | 180 ~ 500ul. |
| Temperatur Reaksi | 37C, Fluctuation 0.3C. |
| Print Out | Built in thermal printer, external printer optional. |
Chemray 240
Rated 0 out of 5
In stock
SKU:
PGA-CHEMRAY240
| Throughput | Lebih dari 160 test / jam. |
|---|---|
| Konten Pengujian | Clinical Chemistry, Immunoturbidimetric. |
| Mode Analisa | End-point, Two-point, Kinetic. |
| Programming | Open system with user defined programs. |
| Otomatis | Akses Acak. |
| Posisi Sampel | 40 posisi untuk sampel. |
| Ukuran Sampel | 3 ~ 100 uL, 0,5 uL adjustable. |
| Posisi Reagent | 40 Posisi untuk Reagent. Refrigerated Temperatre : 16C |
| Ukuran Reagent | R1 : 180 ~ 450 uL, 1 uL adjustable. R2 : 30 ~ 450 uL, 1 uL adjustable. |
| Posisi Reaksi | 81 cuvettes, 9 cuvettes/strip. |
| Cuvette | 8 Step Washer System. |
| Ukuran Reaksi | 180 ~ 500ul. |
| Temperatur Reaksi | 37C, Fluctuation 0.2C. |
Glory 917
Rated 0 out of 5
In stock
SKU:
PGA-GLORY917-2024
| Machine type | Random access, open reagent & locked reagent (optional) |
|---|---|
| Test Speed | Constant 150 tests/hour (Mono reagent or double reagent) |
| Test Principle | Colorimetric method, turbidimetry |
| Test Method | 1 point end, 2 point end, Fixed-Time, Kinetics |
| Calibration Type | Linear & nonlinear |
| Sample Tray | 40 sample positions |
| Sample Tube | Micro cup & test tube & blood collection tube can be used. ( Φ 12 -13 )mm * ( 25 – 100 ) mm |
| Sample Volume | 2-30μL, step by 0.1μL |
| Sample Probe | Liquid surface detection, timely tracking for liquid volume. Collision avoidance |
| Sample Barcode | Sample barcode reader (optional) |
| Reagent Tray | 80 reagent positions (40 for R1 & 40 for R2), Non-stop cooling system with peltier pad inside, 24 hours 2°C-14°C, open system, could accept any reagent. |
| Reagent Volume | 20-300μl, step by 1μl |
| Reagent Needle | Liquid surface detection, timely tracking for liquid volume. Collision avoidance. |
| Regent Barcode | Regent barcode reader (optional) |
| Reaction tray | 44 reaction cuvettes, new amorphous optical plastics reaction cups, perfect transmittance. |
| Reaction Volume | 150μl-330μl |
| Reaction Time | 10 minutes |
| Temperature | Peltier pad incubation system, reaction temperature (37℃ ± 0.1℃) |
| Mixer | Paddle-type mixing, effective reducing of carry-over |
| Light Source | Halogen lamp |
| Wavelength | 340nm; 405nm; 450nm; 505nm; 546nm; 578nm; 630nm; 700nm(4 more options) |
| Absorbance range | 0-4.0 Abs |
| Resolution | 0.0001 Abs |
| Operation System | Windows XP, Windows 7, Windows 8, Windows 10 |
| Data Processing | Automatic calibration, test combination, effective time management of reagents, serum index, whole process detection, linear expansion of enzyme, blank deduction,dirty cuvette memory , cross infection prevention, patient information memory and association input, automatic report audit, data fuzzy query, report statistics and printing, reference range grading, alarm information classification, user operation privilege classification management. |
| Report Printing | 6 formats optional, surpport custom pattern |
| Interface | TCP/IP network interface |
| Power Supply | AC 110/220V ± 10%, 50/60 Hz, 650W |
| Water Consumption | 6L/hour(maximum) |
| Dimension | 750mm * 560mm * 535mm(L*W*H) |
| Weight | 52 kg |
PUSHKANG MS100
Rated 0 out of 5
In stock
SKU:
PGA-PUSHKANGMS100
| Sample type | Anticoagulant whole blood, plasma, serum, capillary blood |
|---|---|
| Test principle | Photoelectric colorimetry |
| Connection | On-line of LIS system |
| Sample Volume | 140μL |
| Test time | ≦15min |
| Code identification | Automatic identification of QR code for reagent disc |
| Reagent type | Lyophilized reagent |
| Light source | LED lamp |
| Printer | Built-in thermal printer and external printer (wireless printer driver) |
| Operating system | Android 5.1 (5-inch) |
| Memory capacity | 1GB, with expandable 32GB TF card |
| Supply voltage | AC 100V-240V, 50-60HZ |
| Size | 270mm*180mm*155mm |
| Weight | 3 KG, with built-in adapter |
Selectra Pro M
Rated 0 out of 5
In stock
SKU:
PGA-SELECTRAPRO-M
| Kecepatan | Sampai dengan 266 tes per jam Sampai dengan 180 tes per jam pada mode MONO |
|---|---|
| Sumber Cahaya | Lampu Quartz-iodine 12V-20W |
| Fotometrik | Absorbansi – 0.1 hingga 3.0; Resolusi 0,001 Abs. |
| Konsumsi Air | Maksimal ~500 ml per jam, dengan operasi terus menerus |
| Standard dan Regulasi | ce-ivD cb |
| Dimensi | 122 x 75 x 61 cm (P x T x L) |
| Berat | 95kg |
| Antarmuka | Host: RS232 atau Etherhet (TCP/IP) melalui protokol LIS-2A. |
Selectra Pro XL
Rated 0 out of 5
In stock
SKU:
PGA-SELECTRAPRO-XL
| Throughput | Up to 450 photometric and electrolyte tests/hour. |
|---|---|
| Reagent System | 64 refrigerated reagent positions for 10 mL, 25 mL and 50 mL reagent bottles Cooled to 10°C +/- 4°C at normal laboratory conditions All reagent positions can be assigned as R1, R2 and R3. |
| Sample System | 80 barcode readable positions All positions fit 13×75 or 16x 100mm primary and secondary tubes and pediatric cups All positions can be used for calibrators, controls, normal, pediatric and STAT samples |
| Pipetting System | 1000 µL reagent syringe: R1 volume 110-400 µL R2 volume 0-180 µL R3 volume 0-180 µL Programmable in 1 µL steps 100 µL sample syringe: Sample volume 1-30 µL Programmable in 0.1 µL steps Pre programmed ratio selectable from ratios 1:2 up to 1:100 with 3 diluents Pre-heated probe with level detection, collision protection and integrated mixer. |
| Cuvette Rotor | Cost effective, semi-disposable cuvette rotor with 48 cuvettes Up to 10.000 tests per rotor Typical reagent consumption 220 µL per test Measurement temperature 37°C, controlled by Peltier elements. |
| Light Source | Quartz-iodine lamp 12V-20W |
| Wavelength Range | Optical unit with 8 position filter wheel 340, 405, 505, 546, 578, 620, 660, 700 nm standard wavelengths Other wavelengths available on request. |
| Photometric Range | -0.1 to 3.0 Absorbance Resolution 0.001 Abs. |
| Analytical Modes (Single, Dual and Triple reagent system) | Kinetic measurement with linearity check Mono- and bichromatic end point measurement with or without bichromatic reagent blank and/or sample blank correction Two point measurement; with or without slope blank Graphic plot of all measuring points Predilution and automatic reflex dilution as needed Range of calibration models Non-linear calibration curves Prozone check for immunology tests Cut-off declaration Calculated tests. |
| Quality Control | Up to 15 controls can be defined, 3 per test Westgard or Basic QC rules Levey-Jennings plots Quality control statistics. |
| Standards and Regulations | CE -IVD CB UL. |
| Dimensions | 117 x 115 x 80 cm (W x H x D) 46.1 x 45.3 x 31.5 in(W x H x D) |
| Weight | 190 kg (419 lbs). |
| Interface | Host-Query interface available Host: RS 232 or Ethernet (TCP/IP) through LIS-2A protocol. |
| Environmental Conditions | Temperature: 15 – 32 °C (59 – 90 °F) Humidity: 15 – 88% RH Altitude: up to 2000 m Plumbing: No dedicated water or drain required Electrical: Voltage: 100 – 240 Vac Frequency: 50 – 60 Hz Power (max): 380 VA . |
| Integrated PC | Touch screen navigation Operating system: Windowsâ„¢ XP |
| Barcode Reader | Hand held CCD barcode reader used for reagent identification |
| Eco Kit | Enables separate collection of concentrated measurement mixture and dilute (wash) waste |
| Dry ISE Module | Patented Solid State Electrode Technology Indirect measurement Dilution 1:14 Measures Sodium, Potassium, Chloride and CO2. |
| Positive Sample Identification | Positive Sample Identification (PSID) reads all popular barcodes. |
| Printer | Printer supported by MS Windowsâ„¢. |
| ProActive Maintenance Kit | Complete parts kit for annual preventive maintenance. |
Selectra Pro XS
Rated 0 out of 5
In stock
SKU:
PGA-SELECTRAPRO-XS
| Throughput | Up to 75 tests per hour. |
|---|---|
| Reagent System | Inner rotor ring: 15 reagent positions for 10 ml, 25 ml and 50 ml reagent bottles Optionally cooled to 10°C +/ 4°C at normal laboratory conditions. Outer rotor ring: 25 positions for (STAT) samples, controls and calibrators 15 positions for reagent bottles All positions fit 13×75 mm primary and secondary tubes and pediatric cups All positions can be used for calibrators, controls, normal, pediatric and STAT samples. |
| Pipetting System | 100 μl reagent syringe: – R1 volume 110-400 μl – R2 volume 0-180 μl -R3 volume 0-180 μl – Programmable in 1 μl steps 100 μl sample syringe: – Sample volume 1-30 μl – Programmable in 0.1 μl steps – Programmable dilution ratios 1:5 up to 1:100 in one step increments with 3 possible diluents Pre-heated probe with level detection, collision protection and integrated mixer. |
| Cuvette Rotor | Disposable cuvette rotor with 48 cuvettes Minimum measurement volume 220 μl Measurement temperature 37°C, controlled by Peltier elements. |
| Light Source | Quartz-iodine lamp 12V-20W. Wavelength Range Optical unit with 8 position filter wheel Automatic wavelength selection 340, 405, 505, 546, 578, 620, 660 nm standard installed One free position Other wavelenghts available on request. |
| Photometric Range | -0.1 to 3.0 Absorbance Resolution 0.001 Abs. |
| Analytical Modes (Single, Dual and Triple reagent system) | Kinetic measurement with linearity check Mono and bichromatic end point measurement with or without bichromatic reagent blank and/or sample blank correction Two point measurement; with or without slope blank Graphic plot of all measuring points Automatic rerun with sample reduction Non-linear calibration curves Prozone check for immunology tests Cut-off declaration Calculated tests. |
| Quality Control | Up to 15 different controls can be defined, 3 per test Westgard rules Levey-Jennings plots Quality control statistics. |
| Standards and Regulations | CE -IVD CB. |
| Dimensions | 89 x 58 x 60 cm (W x H x D) No peripherals |
| Weight | 67 kg. |
| Interface | State of the art Host-Query interface available Host: RS 232 or Ethernet (TCP/IP) through LIS-2A protocol. |
| Environmental Conditions | Temperature: 15 – 32 °C Humidity: 15 – 85% RH Altitude: up to 2,000 m Plumbing: No dedicated water or drain required Electrical: – Voltage: 100 – 240 Vac – Frequency: 50 – 60 Hz – Power (max): 350 VA . |
| Barcode Reader | Hand held CCD bar code reader used for test requisition, reagent identification and automated programing of assays, controls, and calibrators. |
| Printer | Printer supported by MS Windowsâ„¢ |
| ProActive Maintenance Kit | Complete parts kit for annual preventive maintenance. |